The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Kinetics and mechanism of metal–organic framework thin film growth: systematic investigation of HKUST-1 deposition on QCM electrodes
Abstract
We describe a systematic investigation of the factors controlling step-by-step growth of the metal–organic framework (MOF) [Cu3(btc)2(H2O)3]·xH2O (also known as HKUST-1), using quartz crystal microbalance (QCM) electrodes as an in situ probe of the reaction kinetics and mechanism. Electrodes coated with silica, alumina and gold functionalized with OH– and COOH–terminated self-assembled monolayers (SAMs) were employed to determine the effects of surface properties on nucleation. Deposition rates were measured using the high sensitivity available from QCM-D (D = dissipation) techniques to determine rate constants in the early stage of the process. Films were characterized using grazing incidence XRD, SEM, AFM, profilometry and reflection–absorption IR spectroscopy. The effects of reaction time, concentration, temperature and substrate on the deposition rates, film crystallinity and surface morphology were evaluated. The initial growth step, in which the surface is exposed to copper ions (in the form of an ethanolic solution of copper(II) acetate) is fast and independent of temperature, after which all subsequent steps are thermally activated over the temperature range 22–62 °C. Using these data, we propose a kinetic model for the Cu3(btc)2 growth on surfaces that includes rate constants for the individual steps. The magnitude of the activation energies, in particular the large entropy decrease, suggests an associative reaction with a tight transition state. The measured activation energies for the step-by-step MOF growth are an order of magnitude lower than the value previously reported for bulk Cu3(btc)2 crystals. Finally, the results of this investigation demonstrate that the QCM method is a powerful tool for quantitative, in situ monitoring of MOF growth in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal-organic framework materials as catalysts
Lee, J., Farha, O. K., Roberts, J., Scheidt, K. A., Nguyen, S. T., & Hupp, J. T. (2009) · Chemical Society Reviews · doi:10.1039/b807080f · Cited by 7,969
Metal-organic frameworks with high capacity and selectivity for harmful gases
Britt, D., Tranchemontagne, D., & Yaghi, O. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804900105 · Cited by 958
Cited by
Liu, J., & Wöll, C. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00315c · Cited by 698
The surface chemistry of metal–organic frameworks
McGuire, C. V., & Forgan, R. S. (2015) · Chemical Communications · doi:10.1039/c4cc04458d · Cited by 396
Metadata
- Authors
- Stavila, V., Volponi, J., Katzenmeyer, A. M., Dixon, M. C., & Allendorf, M. D.
- Venue
- Chemical Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 3
- Issue
- 5
- Pages
- 1531
- ISSN
- 2041-6520 (ISSN-L)
- 2041-6539
- OpenAlex
- W2137687873
- Cited by
- 195
- References
- 2
- FWCI
- 8.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinetics and mechanism of metal–organic framework thin film growth: systematic investigation of HKUST-1 deposition on QCM electrodes. https://app.cochat.ai/papers/10.1039/c2sc20065a
- The paper
- Stavila, V., Volponi, J., Katzenmeyer, A. M., Dixon, M. C., & Allendorf, M. D. (2012). Kinetics and mechanism of metal–organic framework thin film growth: systematic investigation of HKUST-1 deposition on QCM electrodes. Chemical Science. https://doi.org/10.1039/c2sc20065a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.