The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Harnessing thermal fluctuations for purposeful activities: the manipulation of single micro-swimmers by adaptive photon nudging
Abstract
A simple scheme is presented for remotely maneuvering individual microscopic swimmers by means of on-demand photo-induced actuation, where a laser gently and intermittently pushed the swimmer along its body axis (photon nudging) through a combination of radiation-pressure force and photophoretic pull. The proposed strategy utilized rotational random walks to reorient the micro-swimmer and turned on its propulsion only when the swimmer was aligned with the target location (adaptive control). A Langevin-type equation of motion was formulated, integrating these two ideas to describe the dynamics of the stochastically controlled swimmer. The strategy was examined using computer simulations and illustrated in a proof-of-principle experiment steering a gold-coated Janus micro-sphere moving in three dimensions. The physical parameters relevant to the two actuating forces under the experimental conditions were investigated theoretically and experimentally, revealing that a ∼7 K temperature differential on the micro-swimmer surface could generate a propelling photophoretic strength of ∼0.1 pN. The controllability and positioning error were discussed using both experimental data and Langevin dynamics simulations, where the latter was further used to identify two key unitless control parameters for manipulation accuracy and efficiency; they were the number of random-walk turns the swimmer experienced on the experimental timescale (the revolution number) and the photon-nudge distance within the rotational diffusion time (the propulsion number). A comparison of simulation and experiment indicated that a near-optimal micron-precision motion control was achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of the Noble Metals
Johnson, P. B., & Christy, R. W. (1972) · Physical Review B · doi:10.1103/physrevb.6.4370 · Cited by 20,094
Cited by
Chemically Powered Micro‐ and Nanomotors
Sánchez, S., Soler, L., & Katuri, J. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201406096 · Cited by 1,011
Small power: Autonomous nano- and micromotors propelled by self-generated gradients
Wang, W., Duan, W., Ahmed, S., Mallouk, T. E., & Sen, A. (2013) · Nano Today · doi:10.1016/j.nantod.2013.08.009 · Cited by 716
Light-driven micro/nanomotors: from fundamentals to applications
Xu, L., Mou, F., Gong, H., Luo, M., & Guan, J. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00516d · Cited by 628
Self-Propelled Micromotors for Cleaning Polluted Water
Soler, L., Magdanz, V., Fomin, V. M., Sanchez, S., & Schmidt, O. G. (2013) · ACS Nano · doi:10.1021/nn405075d · Cited by 560
The 2020 motile active matter roadmap
Gompper, G., Winkler, R. G., Speck, T., Solon, A., Nardini, C., Peruani, F., Löwen, H., Golestanian, R., Kaupp, U. B., Alvarez, L., et al. (2020) · Journal of Physics: Condensed Matter · doi:10.1088/1361-648x/ab6348 · Cited by 468
Self-citation
Metadata
- Authors
- Qian, B., Montiel, D., Bregulla, A., Cichos, F., & Yang, H.
- Venue
- Chemical Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 4
- Issue
- 4
- Pages
- 1420
- ISSN
- 2041-6520 (ISSN-L)
- 2041-6539
- OpenAlex
- W2158559093
- Cited by
- 192
- References
- 1
- FWCI
- 12.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.