Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Carbon dots and chitosan composite film based biosensor for the sensitive and selective determination of dopamine

Huang, Qitong, Hu, Shirong, Zhang, Hanqiang, Chen, Jianhua, He, Yasan, Li, Feiming, Weng, Wen, Ni, Jiancong, Bao, Xiuxiu, Lin, Yi·2013·The Analyst

Abstract

A simple, sensitive and reliable dopamine (DA) biosensor was developed based on a carbon dots (CDs) and chitosan (CS) composite film modified glassy carbon electrode (CDs-CS/GCE). Under optimal conditions, the CDs-CS/GCE showed a better electrochemical response for the detection of DA than that of the glassy carbon electrode (GCE). The oxidation peak current (Ipa) of DA was linear with the concentration of DA in the range from 0.1 μM to 30.0 μM with the limit of detection as 11.2 nM (3S/N). The CDs-CS/GCE was applied to the detection of DA content in an injection solution of DA with satisfactory results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3an00510k

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 169

Metadata

Authors
Huang, Q., Hu, S., Zhang, H., Chen, J., He, Y., Li, F., Weng, W., Ni, J., Bao, X., & Lin, Y.
Venue
The Analyst
Published
2013
Volume
138
Issue
18
Pages
5417
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W2097348019
Cited by
169
References
1
FWCI
9.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Carbon dots and chitosan composite film based biosensor for the sensitive and selective determination of dopamine. https://app.cochat.ai/papers/10.1039/c3an00510k
The paper
Huang, Q., Hu, S., Zhang, H., Chen, J., He, Y., Li, F., Weng, W., Ni, J., Bao, X., & Lin, Y. (2013). Carbon dots and chitosan composite film based biosensor for the sensitive and selective determination of dopamine. The Analyst. https://doi.org/10.1039/c3an00510k

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.