High selectivity imaging of nitroreductase using a near-infrared fluorescence probe in hypoxic tumor
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A highly selective and sensitive near-infrared (NIR) fluorescence probe (Cy-NO2) for imaging nitroreductase was developed and was successfully applied to investigating the relationship between epithelial-mesenchymal transitions (EMTs) in tumour progression and intracellular hypoxic level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The basics of epithelial-mesenchymal transition
Kalluri, R., & Weinberg, R. A. (2009) · Journal of Clinical Investigation · doi:10.1172/jci39104 · Cited by 10,196
Cited by
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Three-dimensional culture systems in cancer research: Focus on tumor spheroid model
Nath, S., & Devi, G. R. (2016) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2016.03.013 · Cited by 919
Macro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
Chemical Design and Synthesis of Functionalized Probes for Imaging and Treating Tumor Hypoxia
Liu, J.-N., Bu, W., & Shi, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00525 · Cited by 838
Fluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827
Ultrasensitive Near-Infrared Fluorescence-Enhanced Probe for in Vivo Nitroreductase Imaging
Li, Y., Sun, Y., Li, J., Su, Q., Yuan, W., Dai, Y., Han, C., Wang, Q., Feng, W., & Li, F. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b04097 · Cited by 516
Fundamentals and developments in fluorescence-guided cancer surgery
Mieog, J. S. D., Achterberg, F. B., Zlitni, A., Hutteman, M., Burggraaf, J., Swijnenburg, R.-J., Gioux, S., & Vahrmeijer, A. L. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-021-00548-3 · Cited by 389
Small Molecule as Fluorescent Probes for Monitoring Intracellular Enzymatic Transformations
Singh, H., Tiwari, K., Tiwari, R., Pramanik, S. K., & Das, A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00379 · Cited by 343
Liu, J., Liu, Y., Bu, W., Bu, J., Sun, Y., Du, J., & Shi, J. (2014) · Journal of the American Chemical Society · doi:10.1021/ja5042989 · Cited by 332
Development of Azo‐Based Fluorescent Probes to Detect Different Levels of Hypoxia
Piao, W., Tsuda, S., Tanaka, Y., Maeda, S., Liu, F., Takahashi, S., Kushida, Y., Komatsu, T., Ueno, T., Terai, T., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201305784 · Cited by 293
Hypoxia-responsive nanoparticle based drug delivery systems in cancer therapy: An up-to-date review
Kumari, R., Sunil, D., & Ningthoujam, R. S. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.12.041 · Cited by 263
Metadata
- Authors
- Xu, K., Wang, F., Pan, X., Liu, R., Ma, J., Kong, F., & Tang, B.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 49
- Issue
- 25
- Pages
- 2554
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2100486273
- Cited by
- 141
- References
- 1
- FWCI
- 6.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.