Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 164

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Ionic liquid lubrication: influence of ion structure, surface potential and sliding velocity

Li, Hua, Rutland, Mark W., Atkin, Rob·2013·Physical Chemistry Chemical Physics

Abstract

Colloid probe atomic force microscopy (AFM) has been employed to investigate the nanotribology of the ionic liquid (IL)-Au(111) interface. Data is presented for four ILs, 1-ethyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([EMIM] FAP), 1-butyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([BMIM] FAP), 1-hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([HMIM] FAP) and 1-butyl-3-methylimidazolium iodide ([BMIM] I), at different Au(111) surface potentials. Lateral forces vary as a function of applied surface potential and ion structure because the composition of the confined ion layer changes from cation-enriched (at negative potentials) to mixed (at 0 V), and to anion-enriched (at positive potentials). ILs with FAP(-) anions all exhibit similar nanotribology: low friction at negative potentials and higher friction at positive potentials. [BMIM] I displays the opposite behaviour, as an I(-) anion-enriched layer is more lubricating than either the [BMIM](+) or FAP(-) layers. The effect of cation charged group (charge-delocalised versus charged-localised) was investigated by comparing [BMIM] FAP with 1-butyl-1-methylpyrrolidinium tris(pentafluoroethyl)trifluorophosphate ([Py(1,4)] FAP). [BMIM] FAP is less lubricating at negative potentials, but more lubricating at positive potentials. This indicated that even at positive potentials the cation concentration in the boundary layer is sufficiently high to influence lubricity. The influence of sliding velocity on lateral force was investigated for the [EMIM] FAP-Au(111) system. At neutral potentials the behaviour is consistent with a discontinuous sliding process. When a positive or negative potential bias is applied, this effect is less pronounced as the colloid probe slides along a better defined ion plane.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3cp52638k

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 164

Metadata

Authors
Li, H., Rutland, M. W., & Atkin, R.
Venue
Physical Chemistry Chemical Physics
Published
2013
Volume
15
Issue
35
Pages
14616
ISSN
  • 1463-9076 (ISSN-L)
  • 1463-9084
OpenAlex
W1984850851
Cited by
164
References
2
FWCI
26.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ionic liquid lubrication: influence of ion structure, surface potential and sliding velocity. https://app.cochat.ai/papers/10.1039/c3cp52638k
The paper
Li, H., Rutland, M. W., & Atkin, R. (2013). Ionic liquid lubrication: influence of ion structure, surface potential and sliding velocity. Physical Chemistry Chemical Physics. https://doi.org/10.1039/c3cp52638k

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.