The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Recent progress in luminescent and colorimetric chemosensors for detection of thiols
Abstract
In the past few decades, the development of optical probes for thiols has attracted great attention because of the biological importance of the thiol-containing molecules such as cysteine (Cys), homocysteine (Hcy), and glutathione (GSH). This tutorial review focuses on various thiol detection methods based on luminescent or colorimetric spectrophotometry published during the period 2010-2012. The discussion covers a diversity of sensing mechanisms such as Michael addition, cyclization with aldehydes, conjugate addition-cyclization, cleavage of sulfonamide and sulfonate esters, thiol-halogen nucleophilic substitution, disulfide exchange, native chemical ligation (NCL), metal complex-displace coordination, and nanomaterial-related and DNA-based chemosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Self-citation
Cited by
BODIPY-based probes for the fluorescence imaging of biomolecules in living cells
Kowada, T., Maeda, H., & Kikuchi, K. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00030k · Cited by 1,381
Design strategies of fluorescent probes for selective detection among biothiols
Niu, L.-Y., Chen, Y.-Z., Zheng, H.-R., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00152h · Cited by 870
Yin, J., Kwon, Y., Kim, D., Lee, D., Kim, G., Hu, Y., Ryu, J.-H., & Yoon, J. (2014) · Journal of the American Chemical Society · doi:10.1021/ja412628z · Cited by 599
Self-citationTheranostic Fluorescent Probes
Sharma, A., Verwilst, P., Li, M., Ma, D., Singh, N., Yoo, J., Kim, Y., Yang, Y., Zhu, J.-H., Huang, H., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00778 · Cited by 499
Self-citationTumor microenvironment-responsive intelligent nanoplatforms for cancer theranostics
Gong, F., Yang, N., Wang, X., Zhao, Q., Chen, Q., Liu, Z., & Cheng, L. (2020) · Nano Today · doi:10.1016/j.nantod.2020.100851 · Cited by 359
Metadata
- Authors
- Jung, H. S., Chen, X., Kim, J. S., & Yoon, J.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 42
- Issue
- 14
- Pages
- 6019
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2106043440
- Cited by
- 882
- References
- 2
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.