The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A flexible Eu(iii)-based metal–organic framework: turn-off luminescent sensor for the detection of Fe(iii) and picric acid
Abstract
A metal-organic framework (MOF) {[Eu2(MFDA)2(HCOO)2(H2O)6]·H2O}n (1) (H2MFDA = 9,9-dimethylfluorene-2,7-dicarboxylic acid) has been solvothermally synthesized and structurally characterized. 1 possesses the three-dimensional pcu type rod-packing structure with one-dimensional rhombic channels. The framework of 1 can reversibly shrink/swell along the c axis upon partial/full release of the water molecules. Correspondingly, the rhombic channels become narrow/large and 1 transforms to narrow-pore 1a/large-pore 1b. 1, 1a and 1b have almost the same excitation and emission spectra with the strong characteristic red-light-emission of Eu(III). A high photoluminescence quantum yield of 77% and long luminescence lifetime of around 1.1 ms was observed for 1. The potential of 1b for Fe(3+) ions and PA sensing was studied in DMF through the luminescence quenching experiments, which show 1b is a potential turn-off luminescent sensory material for the selective detection of Fe(3+) ions and PA with detection limits of around 10(-7) M for both of them. The fluorescence quenching mechanism for Fe(3+) ions and PA was also investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal-organic framework materials as catalysts
Lee, J., Farha, O. K., Roberts, J., Scheidt, K. A., Nguyen, S. T., & Hupp, J. T. (2009) · Chemical Society Reviews · doi:10.1039/b807080f · Cited by 7,969
Cited by
Wang, B., Yang, Q., Guo, C., Sun, Y., Xie, L.-H., & Li, J.-R. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b00918 · Cited by 423
Joarder, B., Desai, A. V., Samanta, P., Mukherjee, S., & Ghosh, S. K. (2015) · Chemistry – A European Journal · doi:10.1002/chem.201405167 · Cited by 334
Luminescent rare-earth-based MOFs as optical sensors
Mahata, P., Mondal, S. K., Singha, D. K., & Majee, P. (2017) · Dalton Transactions · doi:10.1039/c6dt03419e · Cited by 292
Metadata
- Authors
- Zhou, X.-H., Li, L., Li, H.-H., Li, A., Yang, T., & Huang, W.
- Venue
- Dalton Transactions
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 42
- Issue
- 34
- Pages
- 12403
- ISSN
- 1477-9226 (ISSN-L)
- 1477-9234
- OpenAlex
- W2124772802
- Cited by
- 352
- References
- 1
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A flexible Eu(iii)-based metal–organic framework: turn-off luminescent sensor for the detection of Fe(iii) and picric acid. https://app.cochat.ai/papers/10.1039/c3dt51081f
- The paper
- Zhou, X.-H., Li, L., Li, H.-H., Li, A., Yang, T., & Huang, W. (2013). A flexible Eu(iii)-based metal–organic framework: turn-off luminescent sensor for the detection of Fe(iii) and picric acid. Dalton Transactions. https://doi.org/10.1039/c3dt51081f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.