The DOI matches its Crossref record.
Multiplexed single molecule immunoassays
Open accessAbstract
We have developed a method that enables the multiplexed detection of proteins based on counting single molecules. Paramagnetic beads were labeled with fluorescent dyes to create optically distinct subpopulations of beads, and antibodies to specific proteins were then immobilized to individual subpopulations. Mixtures of subpopulations of beads were then incubated with a sample, and specific proteins were captured on their specific beads; these proteins were then labeled with enzymes via immunocomplex formation. The beads were suspended in enzyme substrate, loaded into arrays of femtoliter wells--or Single Molecule Arrays (Simoa)--that were integrated into a microfluidic device (the Simoa disc). The wells were then sealed with oil, and imaged fluorescently to determine: a) the location and subpopulation identity of individual beads in the femtoliter wells, and b) the presence or absence of a single enzyme associated with each bead. The images were analyzed to determine the average enzyme per bead (AEB) for each bead subpopulation that provide a quantitative parameter for determining the concentration of each protein. We used this approach to simultaneously detect TNF-α, IL-6, IL-1α, and IL-1β in human plasma with single molecule resolution at subfemtomolar concentrations, i.e., 200- to 1000-fold more sensitive than current multiplexed immunoassays. The simultaneous, specific, and sensitive measurement of several proteins using multiplexed digital ELISA could enable more reliable diagnoses of disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Potential-Resolved Multicolor Electrochemiluminescence for Multiplex Immunoassay in a Single Sample
Guo, W., Ding, H., Gu, C., Liu, Y., Jiang, X., Su, B., & Shao, Y. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b09422 · Cited by 364
Yang, S.-M., Lv, S., Zhang, W., & Cui, Y. (2022) · Sensors · doi:10.3390/s22041620 · Cited by 299
Plasma Levels of Aβ42 and Tau Identified Probable Alzheimer’s Dementia: Findings in Two Cohorts
Lue, L.-F., Sabbagh, M. N., Chiu, M.-J., Jing, N., Snyder, N. L., Schmitz, C., Guerra, A., Belden, C. M., Chen, T.-F., Yang, C.-C., et al. (2017) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2017.00226 · Cited by 105
Metadata
- Authors
- Rissin, D. M., Kan, C. W., Song, L., Rivnak, A. J., Fishburn, M. W., Shao, Q., Piech, T., Ferrell, E. P., Meyer, R. E., Campbell, T. G., Fournier, D. R., & Duffy, D. C.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 15
- Pages
- 2902
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2055108575
- Cited by
- 159
- References
- 0
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiplexed single molecule immunoassays. https://app.cochat.ai/papers/10.1039/c3lc50416f
- The paper
- Rissin, D. M., Kan, C. W., Song, L., Rivnak, A. J., Fishburn, M. W., Shao, Q., Piech, T., Ferrell, E. P., Meyer, R. E., Campbell, T. G., Fournier, D. R., & Duffy, D. C. (2013). Multiplexed single molecule immunoassays. Lab on a Chip. https://doi.org/10.1039/c3lc50416f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.