The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Smartphone quantifies Salmonella from paper microfluidics
Abstract
Smartphone-based optical detection is a potentially easy-to-use, handheld, true point-of-care diagnostic tool for the early and rapid detection of pathogens. Paper microfluidics is a low-cost, field-deployable, and easy-to-use alternative to conventional microfluidic devices. Most paper-based microfluidic assays typically utilize dyes or enzyme-substrate binding, while bacterial detection on paper microfluidics is rare. We demonstrate a novel application of smartphone-based detection of Salmonella on paper microfluidics. Each paper microfluidic channel was pre-loaded with anti-Salmonella Typhimurium and anti-Escherichia coli conjugated submicroparticles. Dipping the paper microfluidic device into the Salmonella solutions led to the antibody-conjugated particles that were still confined within the paper fibers to immunoagglutinate. The extent of immunoagglutination was quantified by evaluating Mie scattering from the digital images taken at an optimized angle and distance with a smartphone. A smartphone application was designed and programmed to allow the user to position the smartphone at an optimized angle and distance from the paper microfluidic device, and a simple image processing algorithm was implemented to calculate and display the bacterial concentration on the smartphone. The detection limit was single-cell-level and the total assay time was less than one minute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Cited by
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
Optical Biosensors for the Detection of Pathogenic Microorganisms
Yoo, S. M., & Lee, S. Y. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.012 · Cited by 571
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Metadata
- Authors
- Park, T. S., Li, W., McCracken, K. E., & Yoon, J.-Y.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 24
- Pages
- 4832
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2067463380
- Cited by
- 233
- References
- 1
- FWCI
- 12.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.