The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A high-sensitivity near-infrared phototransistor based on an organic bulk heterojunction
Abstract
High-gain photodetectors with near-infrared (NIR) sensitivity are critical for biomedical applications such as photoplethysmography and optical coherence tomography where detected optical signals are relatively weak. Current photodetection technologies rely on avalanche photodiodes and photomultipliers to achieve high sensitivity. These devices, however, require a high operation voltage and are not compatible with CMOS based read-out circuits (ROCs). In this work we demonstrate a solution-proceeded NIR phototransistor structure based on a bulk heterojunction (BHJ) of a narrow bandgap polymer, poly(N-alkyl diketopyrrolo-pyrrole dithienylthieno[3,2-b]thiophene) (DPP-DTT), and [6,6]-phenyl-C61-butyric acid methylester (PCBM). The device exhibits ultrahigh responsivity (∼5 × 10(5) A W(-1)) as well as wide tunability (>1 × 10(4)) of photoconductive gain. Using the current-voltage and transient photocurrent measurements we show that the high responsivity is due to the combined effects of fast transport of holes in the polymer matrix and slow detrapping of electrons from the isolated PCBM domains. The wide gain tunability and the efficient suppression of noise current are achieved through the use of the optically tunable gate terminal. We demonstrate that our phototransistor can be used as the detection unit in a photoplethysmography sensor for non-invasive, continuous finger pulse wave monitoring. The high-sensitivity of the phototransistor allows the use of a low-power light source, thus reducing the overall power consumption of the sensor. This, together with the solution processibility and the simple device configuration (which is compatible with conventional ROCs), make the phototransistor a very promising component for the next generation low-cost, mobile biomedical devices for health monitoring and remote diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235
Cited by
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722
Self-citationHaneef, H. F., Zeidell, A. M., & Jurchescu, O. D. (2020) · Journal of Materials Chemistry C · doi:10.1039/c9tc05695e · Cited by 720
Exploration of Near-Infrared Organic Photodetectors
Li, Q., Guo, Y., & Liu, Y. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.9b00966 · Cited by 328
Wearable Sensing and Telehealth Technology with Potential Applications in the Coronavirus Pandemic
Ding, X., Clifton, D., Ji, N., Lovell, N. H., Bonato, P., Chen, W., Yu, X., Xue, Z., Xiang, T., Long, X., et al. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2992838 · Cited by 281
Self-citation
Metadata
- Authors
- Xu, H., Li, J., Leung, B. H. K., Poon, C. C. Y., Ong, B. S., Zhang, Y., & Zhao, N.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 5
- Issue
- 23
- Pages
- 11850
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2148305153
- Cited by
- 163
- References
- 1
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A high-sensitivity near-infrared phototransistor based on an organic bulk heterojunction. https://app.cochat.ai/papers/10.1039/c3nr03989g
- The paper
- Xu, H., Li, J., Leung, B. H. K., Poon, C. C. Y., Ong, B. S., Zhang, Y., & Zhao, N. (2013). A high-sensitivity near-infrared phototransistor based on an organic bulk heterojunction. Nanoscale. https://doi.org/10.1039/c3nr03989g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.