The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Inkjet printing: an integrated and green chemical approach to microfluidic paper-based analytical devices
Abstract
This paper describes a new method for the fabrication of microfluidic paper-based analytical devices (μPADs) by inkjet printing alone. Microfluidic structures are patterned within less than 5 min on the surface of untreated filter paper by printing a hydrophobic UV curable acrylate composition made of non-volatile and not readily flammable compounds. After ink penetration into the paper and UV curing for 60 s, hydrophobic barriers are formed. Microfluidic channels as narrow as 272 ± 19 μm are achieved. Printed patterns retain their aqueous liquid guiding functionality for at least 6 months when stored at room temperature and for at least 72 h at 50 °C. Printing a thin uniform film on the top of the paper allows the creation of protective layers, resulting in “tunnel-like” sections of microfluidic channels entirely surrounded by inkjet printed hydrophobic barriers. Finally, the same inkjet printer is used to print reagents necessary for colorimetric sensing, which is demonstrated in the example of an enzymatic H2O2 sensor. The detection limit of the μPAD for aqueous H2O2 is 14.4 μM when applying colorimetric data processing. The only equipment required for the entire μPAD fabrication process is an off-the-shelf inkjet printer and a UV light source. This is the first application of standard printing technology for the fully integrated fabrication (microfluidic pattern, back cover, variable pattern depth, enclosed microfluidic structures, biosensor) of entire μPADs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
What is a green solvent? A comprehensive framework for the environmental assessment of solvents
Capello, C., Fischer, U., & Hungerbühler, K. (2007) · Green Chemistry · doi:10.1039/b617536h · Cited by 1,917
Cited by
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Paper‐Based Inkjet‐Printed Microfluidic Analytical Devices
Yamada, K., Henares, T. G., Suzuki, K., & Citterio, D. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411508 · Cited by 501
Self-citationYamada, K., Shibata, H., Suzuki, K., & Citterio, D. (2017) · Lab on a Chip · doi:10.1039/c6lc01577h · Cited by 437
Self-citationRecent developments in computer vision-based analytical chemistry: A tutorial review
Capitán-Vallvey, L. F., López-Ruiz, N., Martínez-Olmos, A., Erenas, M. M., & Palma, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.10.009 · Cited by 341
Metadata
- Authors
- Maejima, K., Tomikawa, S., Suzuki, K., & Citterio, D.
- Venue
- RSC Advances
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 3
- Issue
- 24
- Pages
- 9258
- ISSN
- 2046-2069 (ISSN-L)
- OpenAlex
- W2149317904
- Cited by
- 165
- References
- 1
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.