Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 297

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Thermoelectric properties of Ag-doped Cu2Se and Cu2Te

Ballikaya, Sedat, Chi, Hang, Salvador, James R., Uher, Ctirad · 2013 · Journal of Materials Chemistry A

Abstract

Cu2Se, Cu2Te and Ag-overstoichiometric compounds Cu1.98Ag0.2Se and Cu1.98Ag0.2Te were prepared by melting, annealing, followed by spark plasma sintering compaction. Low and high temperature thermoelectric properties were investigated by measuring the electrical conductivity, Seebeck coefficient, thermal conductivity and Hall coefficient between 2 K and 900 K. Structural analyses were performed by PXRD and SEM-EDX analyses. The Hall and Seebeck coefficients show that holes are the dominant carrier in all compounds. High temperature α–β phase transition in Cu2Se and Cu1.98Ag0.2Se between 350 and 400 K and multiple phase transitions (α–β, β–γ, γ–δ, δ–∈) in Cu2Te and Cu1.98Ag0.2Te between 350 K and 900 K were observed in measurements of heat capacity, temperature dependent PXRD data, and transport coefficients. Low temperature transport measurements (Hall coefficient, electrical conductivity, carrier mobility) strongly suggest the presence of yet another phase transition in Cu2Se, Cu1.98Ag0.2Se, and Cu1.98Ag0.2Te compounds at temperatures between 85 K and 115 K, reported here for the first time. Based on the transport data and structural analysis we conclude that doping Cu2Se and Cu2Te by Ag reduces the density of holes and strongly suppresses the thermal conductivity not only due to a smaller electronic contribution but also due to enhanced point defect scattering of phonons that reduces the lattice portion of the thermal conductivity. Moreover, the phase transition temperature is shifted to lower temperatures upon doping with Ag. The presence of Ag enhances thermoelectric performance of Cu2Te at all temperatures and Cu2Se benefits from Ag doping over a broad range of temperatures up to 700 K. The maximum ZT value of 1.2 at 900 K; 0.52 at 650 K; 0.29 at 900 K; and 1.0 at 900 K were achieved for Cu2Se, Cu1.98Ag0.2Se, Cu2Te and Cu1.98Ag0.2Te, respectively, between 2 K and 900 K.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3ta12508d

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Ballikaya, S., Chi, H., Salvador, J. R., & Uher, C.
Venue
Journal of Materials Chemistry A
Published
2013
Volume
1
Issue
40
Pages
12478
ISSN
  • 2050-7488 (ISSN-L)
  • 2050-7496
OpenAlex
W2171328591
Cited by
297
References
11
FWCI
7.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.