Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid based on nitrogen doped porous carbon nanopolyhedra

Gai, Pengbo, Zhang, Hejing, Zhang, Yunsong, Liu, Wei, Zhu, Gangbing, Zhang, Xiaohua, Chen, Jinhua·2013·Journal of Materials Chemistry B

Abstract

Nitrogen doped porous carbon nanopolyhedra (N-PCNPs) were prepared from direct carbonization of ZIF-8 nanopolyhedra. The N-PCNPs showed uniform morphology, narrow pore-size distribution centered at 3.7 nm, high surface area (2221 m2 g−1) and good electrochemical properties and were used to modify a glassy carbon electrode to electrochemically detect ascorbic acid (AA), dopamine (DA) and uric acid (UA). Compared with the bare GC electrode and reduced graphene oxide modified glassy carbon (rGO/GC) electrode, the N-PCNPs modified GC electrode (N-PCNPs/GC) was found to perform better toward electrocatalytic oxidation of AA, DA and UA. For simultaneous sensing of three analytes, three well-separated voltammetry peaks were obtained using the N-PCNPs/GC electrode in differential pulse voltammetry measurements, and the corresponding peak separations between AA and DA, DA and UA were 228 mV, 124 mV respectively. The linear response ranges for the determination of AA, DA and UA were 80–2000 μM, 0.5–30 μM and 4–50 μM, respectively, and the detection limits (S/N = 3) were 740 nM, 11 nM and 21 nM, respectively. Furthermore, the N-PCNPs/GC electrode showed good reproducibility and stability. The attractive features of N-PCNPs provided potential applications in the simultaneous determination of UA, AA and DA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3tb20215a

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 177

Metadata

Authors
Gai, P., Zhang, H., Zhang, Y., Liu, W., Zhu, G., Zhang, X., & Chen, J.
Venue
Journal of Materials Chemistry B
Published
2013
Volume
1
Issue
21
Pages
2742
ISSN
  • 2050-750X (ISSN-L)
  • 2050-7518
OpenAlex
W2167744038
Cited by
177
References
4
FWCI
13.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid based on nitrogen doped porous carbon nanopolyhedra. https://app.cochat.ai/papers/10.1039/c3tb20215a
The paper
Gai, P., Zhang, H., Zhang, Y., Liu, W., Zhu, G., Zhang, X., & Chen, J. (2013). Simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid based on nitrogen doped porous carbon nanopolyhedra. Journal of Materials Chemistry B. https://doi.org/10.1039/c3tb20215a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.