An e-nose made of carbon nanotube based quantum resistive sensors for the detection of eighteen polar/nonpolar VOC biomarkers of lung cancer

Chatterjee, S., Castro, M., Feller, J. F. · 2013 · Journal of Materials Chemistry B

Abstract

A room temperature operating electronic nose (e-nose) has been developed by the assembly of conductive polymer nanocomposite (CPC) quantum resistive sensors (QRS). The fabrication of QRS by spray layer by layer (sLbL) of CPC solutions allowed us to obtain transducers with reproducible initial properties that could be easily tailored by adjusting either the number of sprayed layers and/or the solution composition. The selectivity of QRS was varied by changing the chemical nature of the polymer matrix in which carbon nanotubes (CNTs) were dispersed in solution, i.e., poly(carbonate) (PC), poly(caprolactone) (PCL), poly(lactic acid) (PLA), poly(styrene) (PS), and poly(methyl methacrylate) (PMMA). The e-nose was then successfully used to detect several volatile organic compounds (VOCs) selected among lung cancer biomarkers: a first set of seven polar vapours (water, ethanol, methanol, acetone, propanol, isopropanol, and 2-butanone), and another set of eleven less and nonpolar vapours (chloroform, toluene, benzene, styrene, cyclohexane, o-xylene, n-propane, n-decane, 1,2,4-trimethyl benzene, isoprene, and 1-hexene). The discrimination ability of the e-nose evaluated after a 3D principal component analysis (PCA) pattern recognition treatment was proved to be very good. Moreover, the quantitativity of the transducers' chemo-resistive responses was well fitted with the Langmuir-Henry-Clustering (LHC) model for both acetone and toluene vapours in a wide range of concentrations. The QRS developed in this study appear to be very good candidates to design low cost e-noses for the anticipated diagnosis of lung cancer by VOC analysis in breath, with ppm level sensitivity (tested down to 2.5 parts per million), short response time (a couple of seconds), low consumption, and a large signal to noise ratio (SNR ≥ 10).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3tb20819b

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 162

Metadata

Authors
Chatterjee, S., Castro, M., & Feller, J. F.
Venue
Journal of Materials Chemistry B
Published
2013
Volume
1
Issue
36
Pages
4563
ISSN
  • 2050-750X (ISSN-L)
  • 2050-7518
OpenAlex
W2145729353
Cited by
162
References
0
FWCI
5.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An e-nose made of carbon nanotube based quantum resistive sensors for the detection of eighteen polar/nonpolar VOC biomarkers of lung cancer. https://app.cochat.ai/papers/10.1039/c3tb20819b
The paper
Chatterjee, S., Castro, M., & Feller, J. F. (2013). An e-nose made of carbon nanotube based quantum resistive sensors for the detection of eighteen polar/nonpolar VOC biomarkers of lung cancer. Journal of Materials Chemistry B. https://doi.org/10.1039/c3tb20819b

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.