Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 178

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

One-step polymer screen-printing for microfluidic paper-based analytical device (μPAD) fabrication

Sameenoi, Yupaporn, Nongkai, Piyaporn Na, Nouanthavong, Souksanh, Henry, Charles S., Nacapricha, Duangjai·2014·The Analyst

Abstract

We report a simple, low-cost, one-step fabrication method for microfluidic paper-based analytical devices (μPAD) using only polystyrene and a patterned screen. The polystyrene solution applied through the screen penetrates through the paper, forming a three-dimensional hydrophobic barrier, defining a hydrophilic analysis zone. The optimal polystyrene concentration and paper types were first investigated. Adjusting polystyrene concentration allows for various types of paper to be used for successful device fabrication. Using an optimized polystyrene concentration with Whatman#4 filter paper, a linear relationship was found to exist between the design width and the printed width. The smallest hydrophilic channel and hydrophobic barrier that can be obtained are 670 ± 50 μm and 380 ± 40 μm, respectively. High device-to-device fabrication reproducibility was achieved yielding a relative standard deviation (%RSD) in the range of 1.12-2.54% (n = 64) of the measured diameter of the well-shaped fabricated test zones with a designed diameter of 5 and 7 mm. To demonstrate the significance of the fabricated μPAD, distance-based and well-based paper devices were constructed for the analysis of H2O2 and antioxidant activity, respectively. The analysis of H2O2 in real samples using distance-based measurement with CeO2 nanoparticles as the colorimetric agent produced the same results at 95% confidence level, as those obtained using KMnO4 titration. A proof-of-concept antioxidant activity determination based on the 2,2-diphenyl-1-picrylhydrazyl (DPPH) assay was also demonstrated. The results verify that the polymer screen-printing method can be used as an alternative method for μPAD fabrication.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c4an01624f

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 178

Metadata

Authors
Sameenoi, Y., Nongkai, P. N., Nouanthavong, S., Henry, C. S., & Nacapricha, D.
Venue
The Analyst
Published
2014-10-15
Volume
139
Issue
24
Pages
6580-6588
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W2131606592
Cited by
178
References
1
FWCI
5.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.