Normal-pressure microwave rapid synthesis of hierarchical SnO2@rGO nanostructures with superhigh surface areas as high-quality gas-sensing and electrochemical active materials
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Hierarchical SnO2@rGO nanostructures with superhigh surface areas are synthesized via a simple redox reaction between Sn(2+) ions and graphene oxide (GO) nanosheets under microwave irradiation. XRD, SEM, TEM, XPS, TG-DTA and N2 adsorption-desorption are used to characterize the compositions and microstructures of the SnO2@rGO samples obtained. The SnO2@rGO nanostructures are used as gas-sensing and electroactive materials to evaluate their property-microstructure relationship. The results show that SnO2 nanoparticles (NPs) with particle sizes of 3-5 nm are uniformly anchored on the surfaces of reduced graphene oxide (rGO) nanosheets through a heteronucleation and growth process. The as-obtained SnO2@rGO sample with a hierarchically sesame cake-like microstructure and a superhigh specific surface area of 2110.9 m(2) g(-1) consists of 92 mass% SnO2 NPs and ∼8 mass% rGO nanosheets. The sensitivity of the SnO2@rGO sensor upon exposure to 10 ppm H2S is up to 78 at the optimal operating temperature of 100 °C, and its response time is as short as 7 s. Compared with SnO2 nanocrystals (5-10 nm), the hierarchical SnO2@rGO nanostructures have enhanced gas-sensing behaviors (i.e., high sensitivity, rapid response and good selectivity). The SnO2@rGO nanostructures also show excellent electroactivity in detecting sunset yellow (SY) in 0.1 M phosphate buffer solution (pH = 2.0). The enhancement in gas-sensing and electroactive performance is mainly attributed to the unique hierarchical microstructure, high surface areas and the synergistic effect of SnO2 NPs and rGO nanosheets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lightcap, I. V., Kosel, T. H., & Kamat, P. V. (2010) · Nano Letters · doi:10.1021/nl9035109 · Cited by 1,044
Cited by
Song, Z., Wei, Z., Wang, B., Luo, Z., Xu, S., Zhang, W., Yu, H., Li, M., Huang, Z., Zang, J., et al. (2016) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b04850 · Cited by 438
Metal oxide nanostructures for sensor applications
Nunes, D., Pimentel, A., Gonçalves, A., Pereira, S., Branquinho, R., Barquinha, P., Fortunato, E., & Martins, R. (2019) · Semiconductor Science and Technology · doi:10.1088/1361-6641/ab011e · Cited by 354
Microwave-assisted synthesis of metal oxide nanostructures for gas sensing application: A review
Mirzaei, A., & Neri, G. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.06.114 · Cited by 344
Li, L., He, S., Liu, M., Zhang, C., & Chen, W. (2015) · Analytical Chemistry · doi:10.1021/ac503234e · Cited by 315
Chen, Z., Wu, R., Liu, M., Wang, H., Xu, H., Guo, Y., Song, Y., Fang, F., Yu, X., & Sun, D. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702046 · Cited by 294
Metadata
- Authors
- Yin, L., Chen, D., Cui, X., Ge, L., Yang, J., Yu, L., Zhang, B., Zhang, R., & Shao, G.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014-10-03
- Volume
- 6
- Issue
- 22
- Pages
- 13690-13700
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2077086521
- Cited by
- 111
- References
- 1
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.