Cited by 50Gas Sensing Nanomaterials and SensorsAdvanced Fiber Optic SensorsFerroelectric and Piezoelectric Materials

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Fast and highly sensitive humidity sensors based on NaNbO 3 nanofibers

Abstract

A humidity sensor based on NaNbO 3 nanofiber networks with fast, ultra-sensitive and selective room-temperature response was fabricated through electrospinning process.

Overview

Integrity signals

Registry

Crossref · 10.1039/c5ra00205b

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 31 references

Cited by

Sorted by citations

Metadata

Authors
Zhang, Y., Pan, X., Wang, Z., Hu, Y., Zhou, X., Hu, Z., & Gu, H.
Affiliations
  • Hubei University (CN)
  • Chongqing University (CN)
  • Hubei University of Science and Technology (CN)
Corresponding author
Wang, Zhao
Venue
RSC Advances
Published
2015
Volume
5
Issue
26
Pages
20453-20458
ISSN
2046-2069 (ISSN-L)
OpenAlex
W2081114448
Cited by
49
References
31
Citations by year
2026: 3 · 2025: 3 · 2024: 7 · 2023: 3 · 2022: 6 · 2021: 2 · 2020: 4 · 2019: 3 · 2018: 5 · 2017: 8 · 2016: 2 · 2015: 3
FWCI
2.89
Type
journal article
Language
en
Open access
closed
Locations
RSC Advances (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
Keywords
humidity sensor, sodium niobate, nanofibers, electrospinning, room-temperature sensing, fast response, high sensitivity, selective detection, nanofiber networks

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review