Ferrofluid-based dispersive liquid-liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats
The DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
An ultrasonic-assisted ferrofluid-based dispersive liquid–liquid microextraction procedure combined with microwave-assisted counter current extraction has been used for the extraction of sixteen polycyclic aromatic hydrocarbons from grilled meat samples.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In case of fluorene was found in two grilled hamburger samples at the concentrations of 319 ± 23 and 436 ± 29 ng kg À1 .”
From Magnetic deep eutectic solvents in microextraction techniques (2022) · cites this paper as [71]
In the citing paper
“Fortunately, the concentration levels are lower that the Commission Regulation (EU) No 835/2011 [71].”
From Magnetic deep eutectic solvents in microextraction techniques (2022) · cites this paper as [71]
In the citing paper
“fluoranthene and pyrene were found in all Kebab Koobideh samples and three of four grilled hamburger samples in the ranges of 319e742 and 386e725 ng kg À1 , respectively.”
From Magnetic deep eutectic solvents in microextraction techniques (2022) · cites this paper as [71]
In the citing paper
“Later, Jouyban et al. [75] also employed Fe 3 O 4 magnetic nanoparticles, in this case, coated with TEOS, combined with menthol, ChCl, and octanoic acid DES for the analysis of polycyclic aromatic hydrocarbons in meat samples.”
From Use of green alternative solvents in dispersive liquid‐liquid microextraction: A review (2022) · cites this paper as [75]
Citations
The citation lists are queued
They are fetched later and appear here then.
References 32 · Cited by 41
Research works printed but not linked: 2
- Farajzadeh, 2019, RSC Adv., 145, 26
- Alipanah pour dil, 2019, J. Chromatogr. A, 460695
Metadata
- Authors
- Jouyban, A., Farajzadeh, M. A., Afshar Mogaddam, M. R., Nemati, M., & Alizadeh Nabil, A. A.
- Affiliations
- Tabriz University of Medical Sciences (IR)
- University of Tabriz (IR)
- Food and Drug Safety Research Center
- Drug Applied Research Center and Faculty of Pharmacy
- Venue
- Analytical Methods
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2020
- Volume
- 12
- Issue
- 11
- Pages
- 1522-1531
- ISSN
- 1759-9660 (ISSN-L)
- 1759-9679
- OpenAlex
- W3008919243
- Cited by
- 41
- References
- 32
- Citations by year
- 2026: 6 · 2025: 5 · 2024: 7 · 2023: 7 · 2022: 4 · 2021: 9 · 2020: 3
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Methods (publishedVersion)
- Funders
- National Institute for Medical Research Development (977374)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- ferrofluids, dispersive liquid-liquid microextraction, deep eutectic solvents, polycyclic aromatic hydrocarbons, grilled meat, ultrasound-assisted extraction, food contamination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ferrofluid-based dispersive liquid-liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats. https://app.cochat.ai/papers/10.1039/d0ay00073f
- The paper
- Jouyban, A., Farajzadeh, M. A., Afshar Mogaddam, M. R., Nemati, M., & Alizadeh Nabil, A. A. (2020). Ferrofluid-based dispersive liquid-liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats. Analytical Methods. https://doi.org/10.1039/d0ay00073f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.