CoChat

Single enzyme electroanalysis

The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.

Abstract

Traditional studies of enzymatic activity rely on the combined kinetics of millions of enzyme molecules to produce a product, an experimental approach that may wash out heterogeneities that exist between individual enzymes. Evaluating these properties on an enzyme-by-enzyme basis represents an unambiguous means of elucidating heterogeneities; however, the quantification of enzymatic activity at the single-enzyme level is fundamentally limited by the maximum catalytic rate, k cat , inherent to a given enzyme. For electrochemical methods measuring current, single enzymes must turn over greater than 10 7 molecules per second to produce a measurable signal on the order of 10 -12 A. Enzymes with this capability are extremely rare in nature, with typical k cat values for biologically relevant enzymes falling between 1 and 10 000 s -1 . Thus, clever amplification strategies are necessary to electrochemically detect the vast majority of enzymes. This review details the progress toward the electroanalytical detection and evaluation of single enzyme kinetics largely focused on the nanoimpact method, a chronoamperometric detection strategy that monitors the change in the current-time profile associated with stochastic collisions of freely diffusing entities (e.g., enzymes) onto a microelectrode or nanoelectrode surface. We discuss the experimental setups and methods developed in the last decade toward the quantification of single molecule enzymatic rates. Special emphasis is given to th…

Overview

Integrity signals

Registry

Crossref · 10.1039/d1an00230a

Cites

62 of 62 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 62 references

Research works printed but not linked: 2

  1. Davis, 2021, Curr. Opin. Electrochem., 25, 2451
  2. Chaudhuri, 2013, Indian J. Biochem. Biophys., 50, 64

Cited by

See all 29

Metadata

Authors
Vannoy, K. J., Ryabykh, A., Chapoval, A. I., & Dick, J. E.
Affiliations
  • University of North Carolina at Chapel Hill (US)
  • Altai State University (RU)
Corresponding author
Dick, Jeffrey E.
Venue
The Analyst
Published
2021
Volume
146
Issue
11
Pages
3413-3421
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W3146653672
Cited by
26
References
62
Citations by year
2026: 4 · 2025: 3 · 2024: 7 · 2023: 6 · 2022: 4 · 2021: 2
FWCI
0.35
Type
journal article
Language
en
Open access
closed
Locations
  • The Analyst (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Science Foundation (CHE-2003587)
Topics
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
chronoamperometric detection, microelectrodes, nanoelectrodes, signal amplification, enzyme activity quantification
MeSH terms
Diffusion, Enzymes, Kinetics, Microelectrodes, Proteins, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Single enzyme electroanalysis. https://app.cochat.ai/papers/10.1039/d1an00230a
The paper
Vannoy, K. J., Ryabykh, A., Chapoval, A. I., & Dick, J. E. (2021). Single enzyme electroanalysis. The Analyst. https://doi.org/10.1039/d1an00230a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.