Improving magnesium's corrosion resistance through tannic acid–polyethyleneimine coatings for bioresorbable implant applications
Open accessAbstract
A TA–PEI coating on magnesium successfully achieved a tolerable corrosion rate for biodegradable implant applications.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
MgF2 and polymeric coatings functioned as dual corrosion-inhibiting barriers: MgF2 physically isolated substrate, and PDA/PEI chemically sequestered Mg2+ via catechol-mediated metal chelation.
“Mechanistically, inorganic MgF2 layer and polymeric coatings might have functioned as dual corrosion-inhibiting barriers (Fig. 2i): the former physically isolated the substrate from corrosive media, while the latter chemically sequestered Mg2+ ions via catechol-mediated metal chelation in the PDA/PEI interlayer [25], preventing substrate dissolution.”
From Nanocatalytic magnesium osteoimplants with biodegradable self-adaptive interfaces for therapeutic repair of infected bone defects (2026) · cites this paper as [25]
Section 3.3.2 reports that TA–PEI coatings reduce corrosion by making it harder for corrosive fluid to reach the Mg substrate, supporting the general polymer-barrier mechanism. But Sections 2.1–2.2 identify the studied coating as tannic acid–PEI, not MgF2 and PDA/PEI; the Introduction describes catechol-mediated crosslinking with PEI, not chelation that sequesters Mg2+. The cited paper therefore does not support the claimed dual-layer composition or chemical mechanism. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 74 · Cited by 8
Research works printed but not linked: 4
- P. E. R. Richard, L. Drake, A. Wayne Vogl, A. W. M. Mitchell and R. M. Tibbitts, Gray's Atlas of Anatomy, International Edition, 2015, pp. 134-206. Available: www.elsevier.com% 0Awww.bookaid.org.
- H. Lee, S. M. Dellatore, W. M. Miller and P. B. Messersmith, Mussel-Inspired Surface Chemistry for Multifunctional Coatings, J. Chem. Inf. Model., 2019, 53(9), 1689-1699.
- M. Serhan, et al., A one-step tannic acid coating to improve cell adhesion and proliferation on polydimethylsiloxane, AIChE Annu. Meet., Conf. Proc., 2020, 44, 15140-15147.
- © 2023 The Author(s). Published by the Royal Society of Chemistry Mater. Adv., 2023, 4, 1590-1603 | 1603
- Authors
- Daniel, Leonardo, M., Nursatya, S. M., Barlian, A., Prajatelistia, E., & Judawisastra, H.
- Affiliations
- Materials Science and Engineering Study Program, Faculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Jl. Ganesha 10, Bandung 40132, Indonesia
- Bandung Institute of Technology (ID)
- Corresponding author
- Prajatelistia, Ekavianty
- Judawisastra, Hermawan
- ORCID
- Venue
- Materials Advances
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2023
- Volume
- 4
- Issue
- 6
- Pages
- 1590-1603
- ISSN
- 2633-5409 (ISSN-L)
- OpenAlex
- W4322749735
- Cited by
- 8
- References
- 74
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 3 · 2023: 1
- FWCI
- 0.51
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Materials Advances (publishedVersion, cc-by)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Magnesium Alloys: Properties and Applications
- Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Physical Sciences › Materials Science › Materials Chemistry › Corrosion Behavior and Inhibition
- Keywords
- magnesium corrosion, tannic acid, polyethyleneimine, biodegradable implants, corrosion resistance, surface coating, corrosion rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›