A flexible wearable strain sensor for human-motion detection and a human–machine interface
Abstract
Electronic skin arrays and smart gloves are designed based on AgNFs/MWCNTs flexible strain sensors to realize motion monitoring and human–computer interactions.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Mechanical sensors detect deformation and contact force using piezoresistive/piezoelectric effects or capacitance changes, and are used for limb flexion analysis, posture adjustment and rehabilitation training.
“Detect deformation and contact force using | piezoresistive/piezoelectric effects or capacitance | changes.”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [206]
The citation lists haven’t been fetched yet
References 50 · Cited by 97
- Authors
- Zhang, H., Zhang, D., Guan, J., Wang, D., Tang, M., Ma, Y., & Xia, H.
- Affiliations
- China University of Petroleum, East China (CN)
- Corresponding author
- Zhang, Dongzhi
- Venue
- Journal of Materials Chemistry C
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2022
- Volume
- 10
- Issue
- 41
- Pages
- 15554-15564
- ISSN
- 2050-7526 (ISSN-L)
- 2050-7534
- OpenAlex
- W4312983092
- Cited by
- 97
- References
- 50
- Citations by year
- 2026: 21 · 2025: 27 · 2024: 33 · 2023: 16
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Materials Chemistry C (publishedVersion)
- Funders
- National Natural Science Foundation of China (51777215)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- wearable strain sensors, flexible electronics, human motion detection, electronic skin, smart glove, human-computer interaction, motion monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review