Cited by 203D Printing in Biomedical ResearchMicrofluidic and Capillary Electrophoresis ApplicationsMicrofluidic and Bio-sensing Technologies

Standalone cell culture microfluidic device-based microphysiological system for automated cell observation and application in nephrotoxicity tests

Open access
Kimura, Hiroshi, Nakamura, Hiroko, Goto, Tomomi, Uchida, Wakana, Uozumi, Takayuki, Nishizawa, Daniel, Shinha, Kenta, Sakagami, Junko +1 more·2024·Lab on a Chip

Abstract

The SCCMD for MPS experiments, which integrates microfluidic chips and their peripherals, complies with the ANSI/SLAS standards and has been seamlessly integrated into an existing automatic cell imaging system for online cell observation.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/d3lc00934c

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 41

  1. U. Marx, T. Akabane, T. B. Andersson, E. Baker, M. Beilmann, S. Beken, S. Brendler-Schwaab, M. Cirit, R. David, E. M. Dehne, I. Durieux, L. Ewart, S. C. Fitzpatrick, O. Frey, F. Fuchs, L. G. Griffith, G. A. Hamilton, T. Hartung, J. Hoeng, H. Hogberg, D. J. Hughes, D. E. Ingber, A. Iskandar, T. Kanamori, H. Kojima, J. Kuehnl, M. Leist, B. Li, P. Loskill, D. L. Mendrick, T. Neumann, G. Pallocca, I. Rusyn, L. Smirnova, T. Steger-Hartmann, D. A. Tagle, A. Tonevitsky, S. Tsyb, M. Trapecar, B. Van de Water, J. Van den Eijnden-van Raaij, P. Vulto, K. Watanabe, A. Wolf, X. Zhou and A. Roth, ALTEX, 2020, 37, 365-394.
  2. H. Kimura, Y. Sakai and T. Fujii, Drug Metab. Pharmacokinet., 2018, 33, 43-48.
  3. L. Lehman-McKeeman and M. Davis, Med. Chem. Res., 2023, 32, 1235-1238.
  4. S. Ishida, Front. Toxicol., 2021, 3, 657765.
  5. H. Kimura, T. Yamamoto, H. Sakai, Y. Sakai and T. Fujii, Lab Chip, 2008, 8, 741-746.
  6. K. Doi, H. Kimura, S. H. Kim, S. Kaneda, T. Wada, T. Tanaka, A. Shimizu, T. Sano, M. Chikamori, M. Shinohara, Y. T. Matsunaga, M. Nangaku and T. Fujii, Lab Chip, 2023, 23, 437-450.
  7. M. Chikamori, H. Kimura, R. Inagi, J. Zhou, M. Nangaku and T. Fujii, Biomicrofluidics, 2020, 14, 044102.
  8. K. Shinha, W. Nihei, T. Ono, R. Nakazato and H. Kimura, Biomicrofluidics, 2020, 14, 044108.
  9. C. M. Sakolish, M. B. Esch, J. J. Hickman, M. L. Shuler and G. J. Mahler, EBioMedicine, 2016, 5, 30-39.
  10. H. C. Huang, Y. J. Chang, W. C. Chen, H. I. C. Harn, M. J. Tang and C. C. Wu, Tissue Eng., Part A, 2013, 19, 2024-2034.
  11. M. Zhou, H. Ma, H. Lin and J. Qin, Biomaterials, 2014, 35, 1390-1401.
  12. E. M. Frohlich, X. Zhang and J. L. Charest, Integr. Biol., 2012, 4, 75-83.
  13. K. J. Jang, A. P. Mehr, G. A. Hamilton, L. A. McPartlin, S. Chung, K. Y. Suh and D. E. Ingber, Integr. Biol., 2013, 5, 1119-1129.
  14. K. J. Jang and K. Y. Suh, Lab Chip, 2010, 10, 36-42.
  15. C. M. Sakolish, B. Philip and G. J. Mahler, Biomicrofluidics, 2019, 13, 014107.
  16. R. B. Sadeghian, R. Ueno, Y. Takata, A. Kawakami, C. Ma, T. Araoka, M. Takasato and R. Yokokawa, Commun. Biol., 2023, 6, 483.
  17. A. Mahadeo, C. K. Yeung, J. Himmelfarb and E. J. Kelly, Curr. Opin. Toxicol., 2022, 30, 100341.
  18. W. Y. Chen, E. A. Evangelista, J. Yang, E. J. Kelly and C. K. Yeung, Front. Pharmacol., 2021, 12, 695920.
  19. H. Kimura, M. Nishikawa, N. Yanagawa, H. Nakamura, S. Miyamoto, M. Hamon, P. Hauser, L. Zhao, O. D. Jo, M. Komeya, T. Ogawa and N. Yanagawa, Biomicrofluidics, 2018, 12, 044107.
  20. Y. Park, C. Depeursinge and G. Popescu, Nat. Photonics, 2018, 12, 578-589.
  21. T. L. Schwinghammer and P. D. Kroboth, J. Clin. Pharmacol., 1988, 28, 388-394.
  22. S. J. Trietsch, G. D. Israëls, J. Joore, T. Hankemeier and P. Vulto, Lab Chip, 2013, 13, 3548-3554.
  23. N. Milani, N. Parrott, D. Ortiz Franyuti, P. Godoy, A. Galetin, M. Gertz and S. Fowler, Lab Chip, 2022, 22, 2853-2868.
  24. T. Satoh, S. Sugiura, K. Shinji, R. Nagasaki, S. Ishida, K. Kikuchi, M. Kakiki and T. Kanamori, Lab Chip, 2017, 18, 115-125.
  25. M. Shinohara, H. Arakawa, Y. Oda, N. Shiraki, S. Sugiura, T. Nishiuchi, T. Satoh, K. Iino, S. Leo, Y. Kato, K. Araya, T. Kawanishi, T. Nakatsuji, M. Mitsuta, K. Inamura, T. Goto, K. Shinha, W. Nihei, K. Komori, M. Nishikawa, S. Kume, Y. Kato, T. Kanamori, Y. Sakai and H. Kimura, Sci. Rep., 2021, 11, 5437.
  26. H. Arakawa, S. Sugiura, T. Kawanishi, K. Shin, H. Toyoda, T. Satoh, Y. Sakai, T. Kanamori and Y. Kato, Lab Chip, 2020, 20, 537-547.
  27. K. S. Nitsche, I. Müller, S. Malcomber, P. L. Carmichael and H. Bouwmeester, Arch. Toxicol., 2022, 96, 711-741.
  28. T. T. Nieskens and M. J. Wilmer, Eur. J. Pharmacol., 2016, 790, 46-56.
  29. R. Fujii, S. Hasegawa, H. Maekawa, T. Inoue, K. Yoshioka, R. Uni, Y. Ikeda, M. Nangaku and R. Inagi, Am. J. Physiol., 2021, 321, F278-F292.
  30. J. A. Deane and S. D. Ricardo, Nephrology, 2007, 12, 559-564.
  31. E. J. Ross, E. R. Gordon, H. Sothers, R. Darji, O. Baron, D. Haithcock, B. Prabhakarpandian, K. Pant, R. M. Myers, S. J. Cooper and N. J. Cox, Sci. Rep., 2021, 11, 14053.
  32. W. Shin and H. J. Kim, Nat. Protoc., 2022, 17, 910-939.
  33. J. D. Irvine, L. Takahashi, K. Lockhart, J. Cheong, J. W. Tolan, H. E. Selick and J. R. Grove, J. Pharm. Sci., 1999, 88, 28-33.
  34. G. Specioso, D. Bovard, F. Zanetti, F. Maranzano, C. Merg, A. Sandoz, B. Titz, F. Dalcanale, J. Hoeng, K. Renggli and L. Suter-Dick, Bioengineering, 2022, 9, 516.
  35. X. Yao, K. Panichpisal, N. Kurtzman and K. Nugent, Am. J. Med. Sci., 2007, 334, 115-124.
  36. N. Nagai, M. Kinoshita, H. Ogata, D. Tsujino, Y. Wada, K. Someya, T. Ohno, K. Masuhara, Y. Tanaka, K. Kato, H. Nagai, A. Yokoyama and Y. Kurita, Cancer Chemother. Pharmacol., 1996, 39, 131-137.
  37. M. E. Ibrahim, C. Chang, Y. Hu, S. L. Hogan, N. Mercke, M. Gomez, C. L. O'Bryant, D. W. Bowles, B. George, X. Wen, B. Buckley, L. Aleksunes and M. S. Joy, Eur. J. Clin. Pharmacol., 2019, 75, 51-57.
  38. P. F. Secker, L. Luks, N. Schlichenmaier and D. R. Dietrich, ALTEX, 2018, 35, 223-234.
  39. Y. A. Guerrero, D. Desai, C. Sullivan, E. Kindt, M. E. Spilker, T. S. Maurer, D. E. Solomon and D. W. Bartlett, AAPS J., 2020, 22, 53.
  40. E. J. Weber, A. Chapron, B. D. Chapron, J. L. Voellinger, K. A. Lidberg, C. K. Yeung, Z. Wang, Y. Yamaura, D. W. Hailey, T. Neumann, D. D. Shen, K. E. Thummel, K. A. Muczynski, J. Himmelfarb and E. J. Kelly, Kidney Int., 2016, 90, 627-637.
  41. X. Chen, R. Roberts, W. Tong and Z. Liu, Toxicol. Sci., 2022, 186, 242-259.

Cited by

Sorted by citations

Authors
Kimura, H., Nakamura, H., Goto, T., Uchida, W., Uozumi, T., Nishizawa, D., Shinha, K., Sakagami, J., & Doi, K.
Affiliations
  • Tokai University (JP)
  • Nikon (Japan) (JP)
  • Institute of Industrial Science, The University of Tokyo (JP)
Corresponding author
Kimura, Hiroshi
Venue
Lab on a Chip
Published
2024
Volume
24
Issue
3
Pages
408-421
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W4390120448
Cited by
20
References
1
Citations by year
2026: 5 · 2025: 11 · 2024: 4
FWCI
1.58
Type
journal article
Language
en
Open access
Locations
  • Lab on a Chip (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
  • Japan Agency for Medical Research and Development (JP20be0304204)
  • Japan Society for the Promotion of Science (JP18H01849, JP21H02824)
  • Tokai University
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
Keywords
microphysiological systems, perfusion culture, organ-on-a-chip
MeSH terms
Microphysiological Systems, Epithelial Cells, Humans, Cell Culture Techniques, Microfluidics, Lab-On-A-Chip Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review