CoChat

A novel cobalt( ii ) acetate complex bearing lutidine ligand: a promising electrocatalyst for oxygen evolution reaction

Open access

The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.

Abstract

A novel [(3,5-lutidine) 2 Co(OAc) 2 (H 2 O) 2 ] complex (1) shows impressive OER activity, two and half times higher than that of a state-of-the-art IrO 2 catalyst.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/d3ra04709a

Cites

65 of 65 references verified0 citation errors · 0 not checkable

Statistics

Figures

Scheme 1 Synthesis scheme of complex 1.
Scheme 1 Synthesis scheme of complex 1.CC BY-NC · PubMed Central
Fig. 1 ORTEP of complex 1 with 50% probability ellipsoid. Selected bond lengths (Å) and angles (°): Co1–O1 2.133(1), Co1–O2 2.068(1), Co1–N1 2.153(2); O1–Co1–O1 180.00(0), O2–Co1–O2 180.00(6), O2–Co1–N1–90.58(5), N1–Co1–N1 180.00(8), O2–Co1–O1 88.55(4), N1–Co1–O1 87.42(5).
Fig. 1 ORTEP of complex 1 with 50% probability ellipsoid. Selected bond lengths (Å) and angles (°): Co1–O1 2.133(1), Co1–O2 2.068(1), Co1–N1 2.153(2); O1–Co1–O1 180.00(0), O2–Co1–O2 180.00(6), O2–Co1–N1–90.58(5), N1–Co1–N1 180.00(8), O2–Co1–O1 88.55(4), N1–Co1–O1 87.42(5).CC BY-NC · PubMed Central
Fig. 2 (a) Packing diagram showing O–H⋯O hydrogen bonding for complex 1. (b) Packing diagram showing the void surfaces in the crystal structure of complex 1, viewed down crystallographic c-axis.
Fig. 2 (a) Packing diagram showing O–H⋯O hydrogen bonding for complex 1. (b) Packing diagram showing the void surfaces in the crystal structure of complex 1, viewed down crystallographic c-axis.CC BY-NC · PubMed Central
Fig. 3 Frontier molecular orbital diagram for complex 1 at iso-surface value = 0.02.
Fig. 3 Frontier molecular orbital diagram for complex 1 at iso-surface value = 0.02.CC BY-NC · PubMed Central
Fig. 4 Molecular electrostatic potential maps for complex 1 (iso-surface value = 0.002).
Fig. 4 Molecular electrostatic potential maps for complex 1 (iso-surface value = 0.002).CC BY-NC · PubMed Central
Fig. 5 Non-covalent interactions and RDG plots for complex 1 (iso-surface value = 0.5).
Fig. 5 Non-covalent interactions and RDG plots for complex 1 (iso-surface value = 0.5).CC BY-NC · PubMed Central
Fig. 6 (a) Comparison of LSV polarization curve for complex 1 and IrO2 at 10 mV s−1 in 1 M KOH, (b) the corresponding Tafel plots, (c) the overpotential comparison at 40 mA cm−2 and (d) the Nyquist plot comparison for complex 1 and IrO2.
Fig. 6 (a) Comparison of LSV polarization curve for complex 1 and IrO2 at 10 mV s−1 in 1 M KOH, (b) the corresponding Tafel plots, (c) the overpotential comparison at 40 mA cm−2 and (d) the Nyquist plot comparison for complex 1 and IrO2.CC BY-NC · PubMed Central
Fig. 7 The CVs (cyclic voltammograms) at different scan rates in the capacitive region for (a) IrO2 and (b) complex 1, (c) the plot of current vs. scan rates for Cdl calculation, (d) the comparison of LSV curves normalized by ECSA for complex 1 and IrO2.
Fig. 7 The CVs (cyclic voltammograms) at different scan rates in the capacitive region for (a) IrO2 and (b) complex 1, (c) the plot of current vs. scan rates for Cdl calculation, (d) the comparison of LSV curves normalized by ECSA for complex 1 and IrO2.CC BY-NC · PubMed Central
Fig. 8 (a) The comparison of TOF at 1.73 V vs. RHE for Co-complex (1) and IrO2, (b) chronoamperometry curve at 1.65 V vs. RHE for 14 hours for Co-complex (1).
Fig. 8 (a) The comparison of TOF at 1.73 V vs. RHE for Co-complex (1) and IrO2, (b) chronoamperometry curve at 1.65 V vs. RHE for 14 hours for Co-complex (1).CC BY-NC · PubMed Central
Fig. 9 XPS core level spectra comparison of (a) Co 2p, (b) O 1s, (c) C 1s and (d) N 1s before and after catalysis of Co-complex (1).
Fig. 9 XPS core level spectra comparison of (a) Co 2p, (b) O 1s, (c) C 1s and (d) N 1s before and after catalysis of Co-complex (1).CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 65 references

Cited by

Metadata

Authors
Tanwar, D., Jain, P., Ahluwalia, D., Sudheendranath, A., Thomas, S. P., Ingole, P. P., & Kumar, U.
Affiliations
  • University of Delhi (IN)
  • Indian Institute of Technology Delhi (IN)
  • Delhi Technological University (IN)
Corresponding author
  • Ingole, Pravin P.
  • Kumar, Umesh
Venue
RSC Advances
Published
2023
Volume
13
Issue
35
Pages
24450-24459
ISSN
2046-2069 (ISSN-L)
OpenAlex
W4385845105
Cited by
19
References
65
Citations by year
2026: 7 · 2025: 8 · 2024: 4
FWCI
0.91
Type
journal article
Language
en
Open access
Locations
  • RSC Advances (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Funders
  • University Grants Commission
  • Science and Engineering Research Board (TAR/2020/000232)
  • Indian Institute of Technology Delhi
Topics
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Electrocatalysts for Energy Conversion
  • Physical Sciences › Chemistry › Inorganic Chemistry › Metal-Catalyzed Oxygenation Mechanisms
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › CO2 Reduction Techniques and Catalysts
Keywords
oxygen evolution reaction, electrocatalysis, heterocyclic ligands, cobalt-based electrocatalysts

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.