The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Colloidal copolymer microgels of N-isopropylacrylamide and acrylic acid: pH, ionic strength and temperature effects
Abstract
Aqueous colloidal microgels have been prepared, based on poly(N-isopropylacrylamide)[poly(NIPAM)], cross-linked with bisacrylamide, containing 5% w/w acrylic acid (AAc) as a comonomer. Transmission electron micrographs of the microgels show that the copolymer microgels are monodisperse spheres. The size of the microgel particles containing 5% AAc has been studied, using dynamic light scattering, as a function of pH (3–10), ionic strength (10–4–10–1M NaCl) and temperature (20–75 °C). The hydrodynamic diameter of the copolymer microgels decrease both with increasing ionic strength (at pH 6 and 25 °C) and reversibly with increasing temperature at pH values of 2.6, 3.4 and 6.5. However, under isothermal conditions in 10–3M NaCl at 25 °C, the hydrodynamic diameter increases in going from pH 3.3–9.4. In addition, the temperature-induced conformational changes in the polymer chains have been followed using high-sensitivity differential scanning calorimetry (HSDSC). A comparison is made with the behaviour of poly(NIPAM) microgel particles, not containing AAc. Explanations are offered to account for the pronounced difference in the physico-chemical properties observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comb-type grafted hydrogels with rapid deswelling response to temperature changes
Yoshida, R., Uchida, K., Kaneko, Y., Sakai, K., Kikuchi, A., Sakurai, Y., & Okano, T. (1995) · Nature · doi:10.1038/374240a0 · Cited by 1,256
Graft copolymers that exhibit temperature-induced phase transitions over a wide range of pH
Chen, G., & Hoffman, A. S. (1995) · Nature · doi:10.1038/373049a0 · Cited by 1,219
A novel approach for preparation of pH-sensitive hydrogels for enteric drug delivery
Dong, L.-C., & Hoffman, A. S. (1991) · Journal of Controlled Release · doi:10.1016/0168-3659(91)90072-l · Cited by 449
Katono, H., Maruyama, A., Sanui, K., Ogata, N., Okano, T., & Sakurai, Y. (1991) · Journal of Controlled Release · doi:10.1016/0168-3659(91)90045-f · Cited by 244
Cited by
Temperature-sensitive aqueous microgels
Pelton, R. (2000) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(99)00023-8 · Cited by 1,897
Soft Nanotechnology with Soft Nanoparticles
Nayak, S., & Lyon, L. A. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200501321 · Cited by 855
Nanogels and Microgels: From Model Colloids to Applications, Recent Developments, and Future Trends
Karg, M., Pich, A., Hellweg, T., Hoare, T., Lyon, L. A., Crassous, J. J., Suzuki, D., Gumerov, R. A., Schneider, S., Potemkin, I. I., et al. (2019) · Langmuir · doi:10.1021/acs.langmuir.8b04304 · Cited by 658
Functional copolymers of N-isopropylacrylamide for bioengineering applications
Rzaev, Z. M. O., Dinçer, S., & Pişkin, E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.01.006 · Cited by 528
Highly pH and Temperature Responsive Microgels Functionalized with Vinylacetic Acid
Hoare, T., & Pelton, R. (2004) · Macromolecules · doi:10.1021/ma035658m · Cited by 428
Novel emulsions stabilized by pH and temperature sensitive microgels
Ngai, T., Behrens, S. H., & Auweter, H. (2005) · Chemical Communications · doi:10.1039/b412330a · Cited by 381
Kratz, K., Hellweg, T., & Eimer, W. (2000) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(00)00490-8 · Cited by 375
Murali Mohan, Y., Lee, K., Premkumar, T., & Geckeler, K. E. (2007) · Polymer · doi:10.1016/j.polymer.2006.10.045 · Cited by 374
Hybrid Microgels Photoresponsive in the Near-Infrared Spectral Range
Gorelikov, I., Field, L. M., & Kumacheva, E. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0448869 · Cited by 329
MICROGELS: Old Materials with New Applications
Das, M., Zhang, H., & Kumacheva, E. (2006) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.36.011205.123513 · Cited by 301
Raula, J., Shan, J., Nuopponen, M., Niskanen, A., Jiang, H., Kauppinen, E. I., & Tenhu, H. (2003) · Langmuir · doi:10.1021/la026872r · Cited by 295
Chang, B., Sha, X., Guo, J., Jiao, Y., Wang, C., & Yang, W. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm10631g · Cited by 273
Photoresponsive Surfactants in Microgel Dispersions
Bradley, M., Vincent, B., Warren, N., Eastoe, J., & Vesperinas, A. (2006) · Langmuir · doi:10.1021/la0523053 · Cited by 52
Self-citation
Metadata
- Authors
- Snowden, M. J., Chowdhry, B. Z., Vincent, B., & Morris, G. E.
- Venue
- Journal of the Chemical Society, Faraday Transactions
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1996
- Volume
- 92
- Issue
- 24
- Pages
- 5013
- ISSN
- 0956-5000 (ISSN-L)
- 1364-5455
- OpenAlex
- W2000978239
- Cited by
- 309
- References
- 4
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.