The DOI matches its Crossref record.
A COLORIMETRIC MICRO-METHOD FOR THE DETERMINATION OF GLUTATHIONE
Open accessAbstract
1. A rapid colorimetric and apparently specific micromethod for the determination of total glutathione in small amounts of tissue is described. Generally, less than 30mg. of tissue is sufficient and this is homogenized in ice-cold 3% metaphosphoric acid. The product is filtered through sintered glass and neutralized or diluted before being added to a cuvette containing phosphate buffer, pH7.1, 5,5'-dithiobis-(2-nitrobenzoic acid), EDTA and glutathione reductase. Addition of NADPH(2) to the system initiates a progressive reduction of 5,5'-dithiobis-(2-nitrobenzoic acid) by catalytic amounts of GSH, and this causes a colour increase at 412mmu. The rate of this change, calculated over 5min., is proportional to the total amount of glutathione present, and consequently unknown concentrations may be determined by reference to standards. 2. A preparation (based on that of Racker, 1955) of a suitable sample of glutathione reductase from yeast is described. 3. A less specific and less sensitive determination of extracted thiol groups with 5,5'-dithiobis-(2-nitrobenzoic acid) at pH8.0, based on observations of Ellman (1959) and Jocelyn (1962), is also described. 4. Although the precise nature of the reaction is not known, evidence is put forward to support a process of cyclo-reduction. GSSG is reduced enzymically to GSH, which reacts with 5,5'-dithiobis-(2-nitrobenzoic acid) to produce a coloured ion: [Formula: see text] (E(max.) 412mmu) and a mixed disulphide. This disulphide reacts with further quantities of GSH to liberate another ion and GSSG, which then re-enters the cycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
[70] Determination of glutathione and glutathione disulfide in biological samples
Anderson, M. E. (1985) · Methods in Enzymology · doi:10.1016/s0076-6879(85)13073-9 · Cited by 2,748
Glutathione monoethyl ester: Preparation, uptake by tissues, and conversion to glutathione
Anderson, M. E., Powrie, F., Puri, R. N., & Meister, A. (1985) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(85)90723-4 · Cited by 353
Energy Metabolism during Apoptosis
Garland, J. M., & Halestrap, A. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.8.4680 · Cited by 207
Medium optimization for glutathione production by Saccharomyces cerevisiae
Liu, C.-H., Hwang, C.-F., & Liao, C.-C. (1999) · Process Biochemistry · doi:10.1016/s0032-9592(98)00055-7 · Cited by 52
Metadata
- Authors
- OWENS, C., & BELCHER, R.
- Venue
- Biochemical Journal
- Publisher
- Portland Press Ltd.
- Published
- 1965-03-01
- Volume
- 94
- Issue
- 3
- Pages
- 705-711
- ISSN
- 0006-2936 (ISSN-L)
- OpenAlex
- W2989138034
- Cited by
- 663
- References
- 0
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A COLORIMETRIC MICRO-METHOD FOR THE DETERMINATION OF GLUTATHIONE. https://app.cochat.ai/papers/10.1042/bj0940705
- The paper
- OWENS, C., & BELCHER, R. (1965). A COLORIMETRIC MICRO-METHOD FOR THE DETERMINATION OF GLUTATHIONE. Biochemical Journal. https://doi.org/10.1042/bj0940705
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.