A computer-supported oxystat system maintaining steady-state O2 partial pressures and simultaneously monitoring O2 uptake in biological systems
Open accessThe DOI matches its Crossref record.
Abstract
A feedback-controlled oxystat system is described maintaining steady-state O2 partial pressures (pO2) between 0.01 mmHg (14 nM-O2) and 150 mmHg (210 microM-O2) and simultaneously monitoring O2 uptake at rates between 0.1 and 120 microM-O2 X min-1 in suspensions of cells, in subcellular fractions and in solutions of enzymes. At pO2 values between 0.2 and 150 mmHg (0.28 and 210 microM-O2) a polarographic O2 sensor was used, and below a pO2 of 0.2 mmHg (0.28 microM-O2) the O2-dependent luminescence of the photobacterium Vibrio fischeri was utilized to monitor the actual pO2. At a selected pO2, O2 supply is maintained by injecting appropriate amounts of O2-saturated aqueous medium into the reaction chamber by using a motor-driven burette. The oxystat system is under control of a computer that reads the O2 sensors, interacts with the motor-driven burette, calculates the O2 uptake from the amounts of O2-saturated medium added, collects data from further measuring devices and provides the documentation of the results during incubation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Defining roles of specific reactive oxygen species (ROS) in cell biology and physiology
Sies, H., Belousov, V. V., Chandel, N. S., Davies, M. J., Jones, D. P., Mann, G. E., Murphy, M. P., Yamamoto, M., & Winterbourn, C. (2022) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-022-00456-z · Cited by 1,735
Zell, R., Geck, P., Werdan, K., & Boekstegers, P. (1997) · Molecular and Cellular Biochemistry · doi:10.1023/a:1006896832582 · Cited by 175
Hypoxia, reactive oxygen, and cell injury
de Groot, H., & Littauer, A. (1989) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(89)90047-6 · Cited by 174
Self-citationWolff, M., Fandrey, J., & Jelkmann, W. (1993) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1993.265.5.c1266 · Cited by 70
Oxygen partial pressure and free intracellular adenosine of isolated cardiomyocytes
Smolenski, R. T., Schrader, J., de Groot, H., & Deussen, A. (1991) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1991.260.4.c708 · Cited by 50
Metadata
- Authors
- Noll, T., de Groot, H., & Wissemann, P.
- Venue
- Biochemical Journal
- Publisher
- Portland Press Ltd.
- Published
- 1986-06-15
- Volume
- 236
- Issue
- 3
- Pages
- 765-769
- ISSN
- 0264-6021 (ISSN-L)
- 1470-8728
- OpenAlex
- W2302589454
- Cited by
- 37
- References
- 0
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.