The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrospray and tandem mass spectrometry in biochemistry
Open accessAbstract
Over the last 20 years, biological MS has changed out of all recognition. This is primarily due to the development in the 1980s of ‘soft ionization’ methods that permit the ionization and vaporization of large, polar, and thermally labile biomolecules. These developments in ionization mode have driven the design and manufacture of smaller and cheaper mass analysers, making the mass spectrometer a routine instrument in the biochemistry laboratory today. In the present review the revolutionary ‘soft ionization’ methods will be discussed with particular reference to electrospray. The mass analysis of ions will be described, and the concept of tandem MS introduced. Where appropriate, examples of the application of MS in biochemistry will be provided. Although the present review will concentrate on the MS of peptides/proteins and lipids, all classes of biomolecules can be analysed, and much excellent work has been done in the fields of carbohydrate and nucleic acid biochemistry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
El-Aneed, A., Cohen, A., & Banoub, J. (2009) · Applied Spectroscopy Reviews · doi:10.1080/05704920902717872 · Cited by 386
Rafts: Scale‐Dependent, Active Lipid Organization at the Cell Surface
Mayor, S., & Rao, M. (2004) · Traffic · doi:10.1111/j.1600-0854.2004.00172.x · Cited by 379
Ambient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
Chace, D. H., Kalas, T. A., & Naylor, E. W. (2002) · Annual Review of Genomics and Human Genetics · doi:10.1146/annurev.genom.3.022502.103213 · Cited by 210
Bischel, H. N., MacManus-Spencer, L. A., Zhang, C., & Luthy, R. G. (2011) · Environmental Toxicology and Chemistry · doi:10.1002/etc.647 · Cited by 182
Metadata
- Authors
- GRIFFITHS, W. J., JONSSON, A. P., LIU, S., RAI, D. K., & WANG, Y.
- Venue
- Biochemical Journal
- Publisher
- Portland Press Ltd.
- Published
- 2001-04-24
- Volume
- 355
- Issue
- 3
- Pages
- 545-561
- ISSN
- 0264-6021 (ISSN-L)
- 1470-8728
- OpenAlex
- W1763558376
- Cited by
- 187
- References
- 1
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrospray and tandem mass spectrometry in biochemistry. https://app.cochat.ai/papers/10.1042/bj3550545
- The paper
- GRIFFITHS, W. J., JONSSON, A. P., LIU, S., RAI, D. K., & WANG, Y. (2001). Electrospray and tandem mass spectrometry in biochemistry. Biochemical Journal. https://doi.org/10.1042/bj3550545
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.