The DOI matches its Crossref record.
Competitive Protein-Binding Assay for 25-Hydroxycholecalciferol
Abstract
1. A competitive protein-binding assay for plasma 25-hydroxycholecalciferol was developed, using Sephadex LH-20 columns for the isolation of the sterol and a partially purified protein from rat serum as the binding protein. 2. The mean plasma 25-hydroxycholecalciferol in eighteen male and female normal volunteers was 38 ± SD 14 pmol/ml (15–2 ± 5–6 ng/ml). 3. Levels of 25-hydroxycholecalciferol in plasma of four male volunteers maintained for 2 months on a diet supplemented with 26·1 nmol (10 μg) of cholecalciferol a day were found to be significantly higher. 4. High correlation was established between plasma 25-hydroxycholecalciferol values obtained by the competitive protein-binding assay and values obtained by bioassay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Determination of vitamin D and its metabolites in plasma from normal and anephric man
Shepard, R. M., Horst, R. L., Hamstra, A. J., & DeLuca, H. F. (1979) · Biochemical Journal · doi:10.1042/bj1820055 · Cited by 369
Hereditary Hypophosphatemic Rickets with Hypercalciuria
Tieder, M., Modai, D., Samuel, R., Arie, R., Halabe, A., Bab, I., Gabizon, D., & Liberman, U. A. (1985) · New England Journal of Medicine · doi:10.1056/nejm198503073121003 · Cited by 298
Need, A. G., Kemp, A., Giles, N., Morris, H. A., Horowitz, M., & Nordin, B. E. C. (2002) · Osteoporosis International · doi:10.1007/s198-002-8342-9 · Cited by 102
Metadata
- Authors
- Edelstein, S., Charman, M., Lawson, D. E. M., & Kodicek, E.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1974-02-01
- Volume
- 46
- Issue
- 2
- Pages
- 231-240
- ISSN
- 0301-0538 (ISSN-L)
- OpenAlex
- W2240021489
- Cited by
- 194
- References
- 0
- FWCI
- 14.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Competitive Protein-Binding Assay for 25-Hydroxycholecalciferol. https://app.cochat.ai/papers/10.1042/cs0460231
- The paper
- Edelstein, S., Charman, M., Lawson, D. E. M., & Kodicek, E. (1974). Competitive Protein-Binding Assay for 25-Hydroxycholecalciferol. Clinical Science. https://doi.org/10.1042/cs0460231
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.