Cited by 32Thermoregulation and physiological responsesEffects of Environmental Stressors on LivestockCardiovascular and exercise physiology

Changes in forearm blood flow at elevated ambient temperature and their role in the apparent impairment of glucose tolerance

Frayn, K. N., Whyte, P. L., Benson, H. A., Earl, D. J., Smith, H. A.·1989·Clinical Science

Abstract

1. Antecubital venous plasma glucose and insulin concentrations after ingestion of 75 g of glucose were higher in six normal subjects when studied at an ambient temperature of 33 degrees C at an ambient temperature of 23 degrees C; the mean area under the glucose-time curve increased from 833 at 23 degrees C to 990 mmol min-1 at 33 degrees C, that for insulin from 5300 to 7900 m-units min 1-1. 2. Core temperature was elevated by 0.5 degree C at 33 degrees C ambient, although there was no marked stress response as judged by plasma levels of catecholamines, cortisol and growth hormone; at 2 h after glucose ingestion, mean noradrenaline levels were lower at 33 degrees C than at 23 degrees C (1.1 at 33 degrees C vs 1.8 nmol/l at 23 degrees C), adrenaline slightly higher (0.18 at 33 degrees C vs 0.09 nmol/l at 23 degrees C), cortisol and growth hormone unchanged. 3. Forearm blood flow was markedly elevated at 33 degrees C ambient (mean total flow 9.1 at 33 degrees C vs 1.8 ml min-1 100 ml-1 at 23 degrees C), as were antecubital venous partial pressure of oxygen (mean 10.1 at 33 degrees C vs 5.6 kPa at 23 degrees C) and oxygen saturation (mean 92% at 33 degrees C vs 70% at 23 degrees C). There was a positive correlation between oxygen saturation and area under the glucose tolerance curve. 4. In separate experiments, arterialized glucose concentrations were measured after glucose ingestion at 23 degrees C ambient.(ABSTRACT TRUNCATED AT 250 WORDS)

Integrity signals

Registry

Crossref · 10.1042/cs0760323

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The arterio-venous difference is not consistent; ambient temperature affects forearm blood flow and venous glucose concentrations.

    “Furthermore, this difference is not consistent; ambient temperature, for instance, affects the rate of blood flow through the forearm and has a marked effect on venous blood glucose concentrations (Frayn et al. 1989).”

    From Glycaemic index methodology (2005) · cites this paper as Frayn et al. 1989

  • In one study, antecubital venous glucose was 4 mmol/l lower than arterialised venous blood at 60 min after glucose ingestion.

    “In one study, the glucose concentration in blood taken from an antecubital vein was 4 mmol/l lower than that in arterialised venous blood at 60 min after ingestion of glucose (Frayn et al. 1989).”

    From Glycaemic index methodology (2005) · cites this paper as Frayn et al. 1989

Cited by

Sorted by citations

Authors
Frayn, K. N., Whyte, P. L., Benson, H. A., Earl, D. J., & Smith, H. A.
Affiliations
University of Oxford (GB)
Venue
Clinical Science
Published
1989-03-01
Volume
76
Issue
3
Pages
323-328
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W2428209287
Cited by
32
References
0
Citations by year
2026: 1 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 3 · 2020: 4 · 2019: 2 · 2018: 3 · 2017: 1 · 2016: 3 · 2014: 2
FWCI
0.52
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Science (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
  • Life Sciences › Agricultural and Biological Sciences › Animal Science and Zoology › Effects of Environmental Stressors on Livestock
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
Keywords
forearm blood flow, ambient temperature, glucose tolerance, hyperthermia, insulin response, core body temperature, catecholamines, norepinephrine, oxygen saturation, glucose ingestion, stress response
MeSH terms
Adult, Blood Glucose, Carbon Dioxide, Drug Tolerance, Female, Forearm, Glucose, Glucose Tolerance Test, Humans, Insulin, Male, Oxygen, Partial Pressure, Regional Blood Flow, Temperature

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review