Long-term reproducibility of Borg scale estimates of breathlessness during exercise
The DOI matches its Crossref record.
Abstract
1. The intensity of breathlessness in normal subjects during exercise was measured on seven occasions over a 40-week study period to assess the long-term repeatability of Borg scale estimates of breathlessness. 2. In all subjects there was a significant correlation (P = 0.0001) between breathlessness and minute ventilation. Minute ventilation measured at each work rate did not differ between the seven exercise tests (P >0.05). 3. There was no significant difference between the mean Borg scores (measured with respect to a given level of ventilation) in 5 of the 7 test weeks (P >0.05). The slope of the relationship Borg score/minute ventilation did not differ between the seven exercise tests (P >0.05). 4. Breathlessness estimation was highly reproducible both after 1 week and after 40 weeks of the study (both P >0.05). 5. The duration without testing between consecutive tests did not affect reproducibility: the mean Borg score was as equally reproducible after an interval of 22 weeks without testing as after an interval of 1 week (P >0.05). 6. The Borg scale provides a reliable technique for studying the sensation of breathlessness over extended time periods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Grant, S., Aitchison, T., Henderson, E., Christie, J., Zare, S., Mc Murray, J., & Dargie, H. (1999) · Chest · doi:10.1378/chest.116.5.1208 · Cited by 535
Paggiaro, P. L., Dahle, R., Bakran, I., Frith, L., Hollingworth, K., & Efthimiou, J. (1998) · The Lancet · doi:10.1016/s0140-6736(97)03471-5 · Cited by 508
Use of exercise testing in the evaluation of interventional efficacy: an official ERS statement
Puente-Maestu, L., Palange, P., Casaburi, R., Laveneziana, P., Maltais, F., Neder, J. A., O'Donnell, D. E., Onorati, P., Porszasz, J., Rabinovich, R., et al. (2016) · European Respiratory Journal · doi:10.1183/13993003.00745-2015 · Cited by 412
Metadata
- Authors
- Wilson, R. C., & Jones, P. W.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1991-04-01
- Volume
- 80
- Issue
- 4
- Pages
- 309-312
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W107130776
- Cited by
- 134
- References
- 0
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term reproducibility of Borg scale estimates of breathlessness during exercise. https://app.cochat.ai/papers/10.1042/cs0800309
- The paper
- Wilson, R. C., & Jones, P. W. (1991). Long-term reproducibility of Borg scale estimates of breathlessness during exercise. Clinical Science. https://doi.org/10.1042/cs0800309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.