Relationship between Plasma Volume, Carotid Baroreceptor Sensitivity and Orthostatic Tolerance
The DOI matches its Crossref record.
Abstract
1. Studies were carried out on 43 otherwise healthy patients referred for investigation for attacks of syncope of unknown cause and on six healthy volunteers. 2. Plasma volume was determined by Evans Blue dye dilution and blood volume was estimated using haematocrit. Carotid baroreceptor sensitivity was determined from the changes in pulse interval in response to subatmospheric pressures applied to the neck overlying the carotid sinuses, and orthostatic tolerance was assessed as the time to presyncope in a test of head-up tilt, followed by the addition of graded lower body suction. 3. Eight patients and one volunteer fainted during head-up tilt alone, 23 patients and two volunteers fainted during tilt with lower body suction at −20 mmHg and 12 patients and three volunteers either fainted during suction at −40 mmHg or tolerated the entire procedure. 4. Although plasma and blood volumes were higher in males than females, the values normalized for either body weight or for calculated lean body mass were not different between male and female patients and asymptomatic volunteers. The subjects showing the greatest resistance to syncope were found to have significantly larger plasma and blood volumes (P < 0.0001) and significantly smaller baroreceptor sensitivities (P < 0.0002) than those who fainted earlier. 5. There was a highly significant positive correlation in all subjects between orthostatic tolerance (time to onset of syncope) and plasma and blood volumes (r = 0.60, P < 0.0001; r = 0.53, P < 0.0002), and highly significant negative correlations between time to syncope and baroreceptor sensitivity (r = −0.61, P < 0.0001) and between baroreceptor sensitivity and plasma and blood volumes (r = −0.54, P < 0.0001; r = −0.31, P < 0.03). 6. These results show that tolerance to orthostatic stress is favoured by large plasma and blood volumes and a low sensitivity of the carotid baroreceptor—heart rate reflex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Rossi, P., Andriesse, G. I., Oey, P. L., Wieneke, G. H., Roelofs, J. M. M., & Akkermans, L. M. A. (1998) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(98)00276-7 · Cited by 767
Kinsella, S. M., & Tuckey, J. P. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/86.6.859 · Cited by 340
Orthostatic hypotension following spinal cord injury: understanding clinical pathophysiology
Claydon, V. E., Steeves, J. D., & Krassioukov, A. (2006) · Spinal Cord · doi:10.1038/sj.sc.3101855 · Cited by 299
El-Sayed, H., & Hainsworth, R. (1996) · Heart · doi:10.1136/hrt.75.2.134 · Cited by 263
Self-citation
Metadata
- Authors
- El-Sayed, H., & Hainsworth, R.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1995-04-01
- Volume
- 88
- Issue
- 4
- Pages
- 463-470
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2406212429
- Cited by
- 103
- References
- 0
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship between Plasma Volume, Carotid Baroreceptor Sensitivity and Orthostatic Tolerance. https://app.cochat.ai/papers/10.1042/cs0880463
- The paper
- El-Sayed, H., & Hainsworth, R. (1995). Relationship between Plasma Volume, Carotid Baroreceptor Sensitivity and Orthostatic Tolerance. Clinical Science. https://doi.org/10.1042/cs0880463
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.