Twenty-Four-Hour Pattern of Blood Pressure and Spectral Analysis of Heart Rate Variability in Diabetic Patients with Various Degrees of Autonomic Neuropathy. Comparison to Standard Cardiovascular Tests

Spallone, Vincenza, Bernardi, Luciano, Maiello, M. Rosaria, Cicconetti, Elena, Ricordi, Luigi, Fratino, Pietro, Menzinger, And Guido · 1996 · Clinical Science
Cited by 43

The DOI matches its Crossref record.

Abstract

We performed four cardiovascular tests of autonomic function (deep breathing, lying to standing, Valsalva manoeuvre, postural hypotension) and simultaneous 24h recordings of blood pressure (BP) and ECG in 35 normotensive diabetic subjects. Autoregressive power spectrum analysis of RR interval variability was applied to 24h ECG recordings to obtain for day and night periods power of low- (0.03-0.15 Hz, LF) and high-frequency (0.18- 0.40 Hz, HF) components, relative markers of sympathetic and vagal activity respectively, and their ratio (LF/HF), assumed as index of sympathovagal balance. Eighteen patients showed normal cardiovascular tests, 6 patients one abnormal heart rate test, 5 patients two abnormal heart rate tests, and 6 patients also abnormal postural hypotension test. In diabetic patients with increasing degree of autonomic neuropathy, there was a progressive reduction of day-night change in systolic BP (p < 0.01), of LF during the day (p < 0.01), of HF during the night (p < 0.04), of day-night change in HF (p < 0.02), and of day-night change in HF/LF (p < 0.03). Day-night change in systolic BP was related to postural hypotension (p < 0.001) and to deep breathing (p < 0.01). Day LF was related to lying to standing (p < 0.001), to postural hypotension (p < 0.005) and to deep breathing (p < 0.007). Night HF was related to deep breathing (p < 0.0002) and to lying to standing (p < 0.02). Day-night change in HF/LF was slightly related to deep breathing, lying to standing, and to postural hypotension (p < 0.04). In a multiple regression analysis including age, diabetes duration, and cardiovascular tests as independent variables, day-night change in BP and day LF were only related to postural hypotension, whereas night HF was related to deep breathing. In conclusion, in diabetic patients with increasing autonomic damage, there is a progressive impairment of nocturnal fall of BP and of sympathetic activity during the day, blunted nocturnal increase of vagal activity and lower circadian variation in sympathovagal balance. The significant but not very close correlation of day-night pattern of BP and sympathovagal activity to standard cardiovascular reflex tests, supports the independent usefulness of 24h BP monitoring and spectral analysis of heart rate variability in diabetic neuropathy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1042/cs0910105supp

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 43

Metadata

Authors
Spallone, V., Bernardi, L., Maiello, M. R., Cicconetti, E., Ricordi, L., Fratino, P., & Menzinger, A. G.
Venue
Clinical Science
Published
1996-12-01
Volume
91
Issue
s1
Pages
105-107
ISSN
0144-9664 (ISSN-L)
OpenAlex
W1261938885
Cited by
43
References
0
FWCI
1.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Twenty-Four-Hour Pattern of Blood Pressure and Spectral Analysis of Heart Rate Variability in Diabetic Patients with Various Degrees of Autonomic Neuropathy. Comparison to Standard Cardiovascular Tests. https://app.cochat.ai/papers/10.1042/cs0910105supp
The paper
Spallone, V., Bernardi, L., Maiello, M. R., Cicconetti, E., Ricordi, L., Fratino, P., & Menzinger, A. G. (1996). Twenty-Four-Hour Pattern of Blood Pressure and Spectral Analysis of Heart Rate Variability in Diabetic Patients with Various Degrees of Autonomic Neuropathy. Comparison to Standard Cardiovascular Tests. Clinical Science. https://doi.org/10.1042/cs0910105supp

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.