Broad-band spectral analysis of 24 h continuous finger blood pressure: comparison with intra-arterial recordings
The DOI matches its Crossref record.
Abstract
The present study compares the spectral characteristics of 24-h blood pressure variability estimated invasively at the brachial artery level with those estimated by measurement of blood pressure at the finger artery using the non-invasive Portapres device. Broad-band spectra (from 3×10-5 to 0.5 Hz) were derived from both finger and intra-brachial pressures recorded simultaneously for 24 h in eight normotensive and twelve hypertensive ambulant subjects. At frequencies lower than 0.07 Hz, higher spectral estimates were obtained by Portapres than by intra-brachial measurements. The maximum overestimation occurred in systolic pressure at around 10-2 Hz, where the amplitude of the oscillations was two times greater when measured by Portapres. A less pronounced overestimation was found for diastolic pressures. The maximum overestimation was greater during daytime than during night-time. At around 0.1 Hz, invasive and non-invasive spectra were similar. At the respiratory frequencies (0.15-0.50 Hz), the power spectra were overestimated by Portapres during daytime, and underestimated at night. These results provide reference information for the correct interpretation of Portapres data in the estimation of 24-h blood pressure spectral power.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The enigma of Mayer waves: facts and models.
JULIEN, C. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.008 · Cited by 670
“[96] Castiglioni P, Parati G, Omboni S, Mancia G, Imholz BP, Wesseling”
BackgroundTime-domain cross-correlation baroreflex sensitivity: performance on the EUROBAVAR data set
Westerhof, B. E., Gisolf, J., Stok, W. J., Wesseling, K. H., & Karemaker, J. M. (2004) · Journal of Hypertension · doi:10.1097/01.hjh.0000125439.28861.ed · Cited by 258
Self-citationStress responsivity and socioeconomic status. A mechanism for increased cardiovascular disease risk?
Steptoe, A. (2002) · European Heart Journal · doi:10.1053/euhj.2001.3233 · Cited by 213
Increasing sleep duration to lower beat‐to‐beat blood pressure: a pilot study
Haack, M., Serrador, J., Cohen, D., Simpson, N., Meier‐Ewert, H., & Mullington, J. M. (2013) · Journal of Sleep Research · doi:10.1111/jsr.12011 · Cited by 149
“Previous data have demonstrated that Portapres values are highly correlated with intra-brachial measures of BP over 24-h periods (Castiglioni et al., 1999).”
BackgroundRepetitive exposure to shortened sleep leads to blunted sleep-associated blood pressure dipping
Yang, H., Haack, M., Gautam, S., Meier-Ewert, H. K., & Mullington, J. M. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001284 · Cited by 69
“Portapres measures have been used extensively to measure 24-h BP variations [13,14].”
Metadata
- Authors
- CASTIGLIONI, P., PARATI, G., OMBONI, S., MANCIA, G., IMHOLZ, B. P. M., WESSELING, K. H., & DI RIENZO, M.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1999-06-16
- Volume
- 97
- Issue
- 2
- Pages
- 129-139
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2043853541
- Cited by
- 60
- References
- 0
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Broad-band spectral analysis of 24 h continuous finger blood pressure: comparison with intra-arterial recordings. https://app.cochat.ai/papers/10.1042/cs0970129
- The paper
- CASTIGLIONI, P., PARATI, G., OMBONI, S., MANCIA, G., IMHOLZ, B. P. M., WESSELING, K. H., & DI RIENZO, M. (1999). Broad-band spectral analysis of 24 h continuous finger blood pressure: comparison with intra-arterial recordings. Clinical Science. https://doi.org/10.1042/cs0970129
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.