Cited by 144Cardiovascular Health and Disease PreventionNitric Oxide and Endothelin EffectsNon-Invasive Vital Sign Monitoring

Nitric oxide modulation of blood vessel tone identified by arterial waveform analysis

McVEIGH, Gary E., ALLEN, Patrick B., MORGAN, David R., HANRATTY, Colm G., SILKE, Bernard·2001·Clinical Science

Abstract

Traditionally, nitric oxide-mediated alteration in blood vessel tone has been inferred from changes in flow in response to physical and pharmacological interventions using plethysmographic or ultrasonic techniques. We hypothesized that alteration in pulsatile arterial function may represent a more sensitive measure to detect and monitor nitric oxide-mediated modulation of arterial smooth muscle tone. Healthy male volunteers (n = 15) had radial artery pressure pulse waveforms recorded using a calibrated tonometer device. A computer-based assessment of the diastolic pressure decay was employed to quantify changes in arterial waveform morphology in terms of altered pulsatile (arterial compliance) and steady-state (peripheral resistance) haemodynamics. NG-nitro-L-arginine methyl ester (L-NAME), a stereospecific inhibitor of nitric oxide synthesis, was infused intravenously in incrementally increasing doses of 0.25, 0.5 and 0.75 mg/kg for 8 min each. Subjects then received either L-arginine or D-arginine (200 mg/kg over 15 min) intravenously in a blinded fashion. On a separate day, subjects had radial artery pressure pulse waveforms recorded before and after the sublingual administration of glyceryl trinitrate, an exogenous donor of nitric oxide. Cardiac output and heart rate decreased and mean arterial blood pressure increased significantly (P < 0.01 for all) in response to the incremental intravenous infusion of L-NAME. Small artery compliance decreased, whereas systemic vascular resistance increased in response to nitric oxide synthesis inhibition (P < 0.01 for both). The intravenous infusion of L-arginine restored the pulsatile and steady-state haemodynamic parameters to pre-treatment values, whereas D-arginine had no effect. Sublingual glyceryl trinitrate decreased systemic vascular resistance by 11%, whereas large artery- and small artery-compliance increased by 25% and 44% respectively. Pressure pulse contour analysis represents a sensitive and convenient technique capable of tracking changes in the pulsatile function of arteries accompanying nitric oxide-mediated alteration in arterial smooth muscle tone.

Integrity signals

Registry

Crossref · 10.1042/cs1000387

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 24 · Cited by 144

Authors
McVEIGH, G. E., ALLEN, P. B., MORGAN, D. R., HANRATTY, C. G., & SILKE, B.
Affiliations
Department of Therapeutics and Pharmacology, Whitla Medical Building, 97 Lisburn Road, Belfast BT9 6BL, Northern Ireland, U.K.
Venue
Clinical Science
Published
2001-02-27
Volume
100
Issue
4
Pages
387-393
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W1983531856
Cited by
144
References
24
Citations by year
2025: 1 · 2024: 2 · 2023: 2 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 6 · 2018: 4 · 2017: 6 · 2016: 6 · 2015: 5 · 2014: 5 · 2013: 4 · 2012: 5
FWCI
4.87
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Science (publishedVersion)
  • PubMed (publishedVersion)
  • Research Portal (Queen's University Belfast) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Physiology › Nitric Oxide and Endothelin Effects
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
nitric oxide, vascular tone, arterial compliance, systemic vascular resistance, L-NAME, L-arginine, D-arginine, nitroglycerin, nitric oxide synthesis inhibition, radial artery pressure waveform, small artery compliance, hemodynamics
MeSH terms
Adult, Compliance, Endothelium, Vascular, Enzyme Inhibitors, Hemodynamics, Humans, Male, Middle Aged, Nitric Oxide, Pulsatile Flow, Vascular Resistance, Radial Artery, Nitric Oxide Synthase, NG-Nitroarginine Methyl Ester

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review