CoChat

Diaphragm electromyography using an oesophageal catheter: current concepts

Luo, Yuan Ming, Moxham, John, Polkey, Michael I. · 2008 · Clinical Science
Cited by 135

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The usefulness of diaphragm electromyography recorded from an oesophageal electrode depends on a reliable signal which is free of artefact. The diaphragm EMG (electromyogram) recorded from chest wall surface electrodes may be unreliable because of signal contamination from muscle activity other than the diaphragm. Initially, the oesophageal electrode catheter for human studies had only one electrode pair, which could be difficult to position accurately and was influenced by a change in lung volume. Recently, a multipair oesophageal electrode has been developed which allows a high-quality EMG to be recorded. In the present review, the progress of oesophageal electrode design is outlined. The effects of signal contamination, electrode movement and particularly the effect of change in lung volume on the diaphragm EMG are discussed. The diaphragm EMG, recorded from a multipair oesophageal electrode, is useful to assess neural respiratory drive and diaphragm function in different groups of patients with respiratory disease, including patients with neuromuscular disease and sleep-disordered breathing, and those in the intensive care unit. When combined with cervical and cranial magnetic stimulation, an oesophageal electrode can be used to partition the central respiratory response time and phrenic nerve conduction time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1042/cs20070348

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 135

Metadata

Authors
Luo, Y. M., Moxham, J., & Polkey, M. I.
Venue
Clinical Science
Published
2008-09-12
Volume
115
Issue
8
Pages
233-244
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W1987605472
Cited by
135
References
1
FWCI
2.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.