The DOI matches its Crossref record.
Guidelines for Selecting Microphones for Human Voice Production Research
Abstract
Purpose: This tutorial addresses fundamental characteristics of microphones (frequency response, frequency range, dynamic range, and directionality), which are important for accurate measurements of voice and speech. Method: Technical and voice literature was reviewed and analyzed. The following recommendations on desirable microphone characteristics were formulated: The frequency response of microphones should be flat (i.e., variation of less than 2 dB) within the frequency range between the lowest expected fundamental frequency of voice and the highest spectral component of interest. The equivalent noise level of the microphones is recommended to be at least 15 dB lower than the sound level of the softest phonations. The upper limit of the dynamic range of the microphone should be above the sound level of the loudest phonations. Directional microphones should be placed at the distance that corresponds to their maximally flat frequency response, to avoid the proximity effect; otherwise, they will be unsuitable for spectral and level measurements. Numerical values for these recommendations were derived for the microphone distances of 30 cm and 5 cm. Conclusions: The recommendations, while preliminary and in need of further numerical justification, should provide the basis for better accuracy and repeatability of studies on voice and speech production in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Patel, R. R., Awan, S. N., Barkmeier-Kraemer, J., Courey, M., Deliyski, D., Eadie, T., Paul, D., Švec, J. G., & Hillman, R. (2018) · American Journal of Speech-Language Pathology · doi:10.1044/2018_ajslp-17-0009 · Cited by 818
Clinical Practice Guideline: Improving Voice Outcomes after Thyroid Surgery
Chandrasekhar, S. S., Randolph, G. W., Seidman, M. D., Rosenfeld, R. M., Angelos, P., Barkmeier‐Kraemer, J., Benninger, M. S., Blumin, J. H., Dennis, G., Hanks, J., et al. (2013) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599813487301 · Cited by 466
Maryn, Y., & Weenink, D. (2015) · Journal of Voice · doi:10.1016/j.jvoice.2014.06.015 · Cited by 271
Assessment of voice quality: Current state-of-the-art
Barsties, B., & De Bodt, M. (2015) · Auris Nasus Larynx · doi:10.1016/j.anl.2014.11.001 · Cited by 265
Guidelines for Speech Recording and Acoustic Analyses in Dysarthrias of Movement Disorders
Rusz, J., Tykalova, T., Ramig, L. O., & Tripoliti, E. (2021) · Movement Disorders · doi:10.1002/mds.28465 · Cited by 170
Metadata
- Authors
- Švec, J. G., & Granqvist, S.
- Venue
- American Journal of Speech-Language Pathology
- Published
- 2010-11
- Volume
- 19
- Issue
- 4
- Pages
- 356-368
- ISSN
- 1058-0360 (ISSN-L)
- 1558-9110
- DOI
- 10.1044/1058-0360(2010/09-0091
- OpenAlex
- W2074875921
- Cited by
- 191
- References
- 0
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Guidelines for Selecting Microphones for Human Voice Production Research. https://app.cochat.ai/papers/10.1044/1058-0360(2010/09-0091
- The paper
- Švec, J. G., & Granqvist, S. (2010). Guidelines for Selecting Microphones for Human Voice Production Research. American Journal of Speech-Language Pathology. https://doi.org/10.1044/1058-0360(2010/09-0091
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.