Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech
The DOI matches its Crossref record; 32 of the 35 references it cites were found in a registry or an index.
Abstract
Purpose: Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to improve their accuracy and reproducibility. Method: Basic information is put together from standards, technical, voice and speech literature, and practical experience of the authors and is explained for nontechnical readers. Results: Variation of SPL with distance, sound level meters and their accuracy, frequency and time weightings, and background noise topics are reviewed. Several calibration procedures for SPL measurements are described for stand-mounted and head-mounted microphones. Conclusions: SPL of voice and speech should be reported together with the mouth-to-microphone distance so that the levels can be related to vocal power. Sound level measurement settings (i.e., frequency weighting and time weighting/averaging) should always be specified. Classified sound level meters should be used to assure measurement accuracy. Head-mounted microphones placed at the proximity of the mouth improve signal-to-noise ratio and can be taken advantage of for voice SPL measurements when calibrated. Background noise levels should be reported besides the sound levels of voice and speech.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Calibration was performed using sustained ‘Ah’ vowels over ≥ 4 s following recommended procedures [34] and guidelines [35], with each recording including a reference reading from the sound level meter, recorded on an A-weighted scale [34].”
From Comparing face-to-face and online LSVT®LOUD speech training using LSVT®Coach in patients with Parkinson’s disease: a pilot randomised controlled trial (2025) · cites this paper as [34]
Citations
Cites
Praat: Doing Phonetics by Computer
(2011) · Ear & Hearing · doi:10.1097/aud.0b013e31821473f7 · Cited by 7,863
Dejonckere, P. H., Bradley, P., Clemente, P., Cornut, G., Crevier-Buchman, L., Friedrich, G., Van De Heyning, P., Remacle, M., & Woisard, V. (2001) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s004050000299 · Cited by 1,161
Kuttruff, H. (1973) · Cited by 1,120
Patel, R. R., Awan, S. N., Barkmeier-Kraemer, J., Courey, M., Deliyski, D., Eadie, T., Paul, D., Švec, J. G., & Hillman, R. (2018) · American Journal of Speech-Language Pathology · doi:10.1044/2018_ajslp-17-0009 · Cited by 818
Self-citationDreschler, W. A., Verschuure, H., Ludvigsen, C., & Westermann, S. (2001) · International Journal of Audiology · doi:10.3109/00206090109073110 · Cited by 320
Evaluation of smartphone sound measurement applications
Kardous, C. A., & Shaw, P. B. (2014) · The Journal of the Acoustical Society of America · doi:10.1121/1.4865269 · Cited by 312
Vocal Dose Measures: Quantifying Accumulated Vibration Exposure in Vocal Fold Tissues
Titze, I. R., Švec, J. G., & Popolo, P. S. (2003) · Journal of Speech, Language, and Hearing Research · doi:10.1044/1092-4388(2003/072 · Cited by 252
Self-citationSchutte, H. K., & Seidner, W. (1983) · Folia Phoniatrica et Logopaedica · doi:10.1159/000265703 · Cited by 225
Howard, D., & Angus, J. (2000) · Routledge eBooks · doi:10.4324/9780080498522 · Cited by 210
Adverse Effects of Environmental Noise on Acoustic Voice Quality Measurements
Deliyski, D. D., Shaw, H. S., & Evans, M. K. (2005) · Journal of Voice · doi:10.1016/j.jvoice.2004.07.003 · Cited by 199
Research works printed but not linked: 25
- ANSI, 1994, ANSI S1.1-1994 (R2004). American National Standard. Acoustical terminology
- ANSI, 2006, ANSI S1.40-2006. American National Standard. Specifications and verification procedures for sound calibrators
- ANSI, 2006, ANSI S3.44-1996 (R2006). American National Standard. Determination of occupational noise exposure and estimation of noise-induced hearing impairment
- ANSI, 2008, ANSI/ASA S12.9-2008/Part 6. American National Standard. Quantities and procedures for description and measurement of environmental sound—Part 6: Methods for estimation of awakenings associated with outdoor noise events heard in homes
- ANSI, 2010, ANSI/ASA S12.60-2010/Part 1. American National Standard. Acoustical performance criteria, design requirements, and guidelines for schools, Part 1: Permanent schools
- ANSI, 2014, ANSI/ASA S1.4 PART 1 2014 Edition. American National Standard. Electroacoustics—Sound level meters—Part 1: Specifications
- Brixen E. B., 1998, Near field registration of the human voice: Spectral changes due to positions (Paper no. 4728)
- Brüel & Kjaer, 1984, Measuring sound
- Cabrera D., 2002, Recording the operatic voice for acoustic analysis, Acoustics Australia, 30, 103
- Cohen E. R., 1987, Symbols, units, nomenclature and fundamental constants in physics. Document I.U.P.A.P.-25 (SUNAMCO 87-1)
- EPA, 1979, EPA/550/9-79-100. Protective noise levels. Condensed version of “Information on levels of environmental noise requisite to protect public health and welfare with an adequate margin of safety, EPA/ONAC 550/9-74-004.”
- Everest F. A., 2001, Master handbook of acoustics
- Howard D. M., 2001, Occupational voice—Care and cure, 29
- IEC, 2003, IEC 60942 ed. 3.0. Electroacoustics—Sound calibrators
- IEC, 2013, IEC 61672-1:2013. Electroacoustics—Sound level meters—Part 1: Specification
- ISO, 2003, ISO 9921:2003(E). Ergonomics—Assessment of speech communication
- ISO, 2007, ISO 80000-8:2007. Quantities and units—Part 8: Acoustics
- ISO, 2007, ISO/TR 25417:2007. Acoustics—Definitions of basic quantities and terms
- Kardous C. A., 2015, Do sound meter apps measure noise levels accurately?, Sound and Vibration, July, 2015, 10
- Liljencrants J., 2004, Elektroakustik [Electroacoustics] (In Swedish). TRITA-TMH 2004-3
- NIOSH, 1998, Criteria for a recommended standard: Occupational noise exposure. Publication No. 98-126
- Pabon P., 2007, Voice profiler (version 4.0)
- Pearsons K., 1976, Speech levels in various noise environments (Rep. No. EPA-600/1-77-02)
- Šrámková H., 2011, Měření dynamického rozsahu lidského hlasu [Measurements of dynamic range of human voice], Akustické listy, 17, 11
- Titze I. R., 2000, Principles of voice production (second printing)
Cited by
Patel, R. R., Awan, S. N., Barkmeier-Kraemer, J., Courey, M., Deliyski, D., Eadie, T., Paul, D., Švec, J. G., & Hillman, R. (2018) · American Journal of Speech-Language Pathology · doi:10.1044/2018_ajslp-17-0009 · Cited by 818
Self-citationGuidelines for Speech Recording and Acoustic Analyses in Dysarthrias of Movement Disorders
Rusz, J., Tykalova, T., Ramig, L. O., & Tripoliti, E. (2021) · Movement Disorders · doi:10.1002/mds.28465 · Cited by 170
“Each recording to be analyzed must include a reference reading of a soundlevel meter placed at the same distance from the microphone, and the reading on the sound-level meter on a C-weighting scale must be recorded.(5) A 1000-Hz steady-state tone is commonly used.”
MethodReview of Recent Development of MEMS Speakers
Wang, H., Ma, Y., Zheng, Q., Cao, K., Lu, Y., & Xie, H. (2021) · Micromachines · doi:10.3390/mi12101257 · Cited by 114
“The reference effective sound pressure value Pre f is 20 μPa [30].”
BackgroundCepstral and Perceptual Investigations in Female Teachers With Functionally Healthy Voice
Phadke, K. V., Laukkanen, A.-M., Ilomäki, I., Kankare, E., Geneid, A., & Švec, J. G. (2018) · Journal of Voice · doi:10.1016/j.jvoice.2018.09.010 · Cited by 114
Self-citationSound-based multiple-equipment activity recognition using convolutional neural networks
Sherafat, B., Rashidi, A., & Asgari, S. (2022) · Automation in Construction · doi:10.1016/j.autcon.2021.104104 · Cited by 59
Perceptual and Acoustic Effects of Dual-Focus Speech Treatment in Children With Dysarthria
Levy, E. S., Chang, Y. M., Hwang, K., & McAuliffe, M. J. (2021) · Journal of Speech Language and Hearing Research · doi:10.1044/2020_jslhr-20-00301 · Cited by 61
“Recording methodology replicated the general approach implemented by LSVT LOUD studies (e.g., Boliek & Fox, 2017; Fox & Boliek, 2012; Ramig et al., 2001) to include the dimension of the (child) participant’s vocal intensity in the signal for later playback (Švec & Granqvist, 2018).”
MethodResultPatel, R. R., Sundberg, J., Gill, B., & Lã, F. M. B. (2020) · Journal of Voice · doi:10.1016/j.jvoice.2020.07.037 · Cited by 43
Broadfoot, C. K., Abur, D., Hoffmeister, J. D., Stepp, C. E., & Ciucci, M. R. (2019) · Perspectives of the ASHA Special Interest Groups · doi:10.1044/2019_pers-sig3-2019-0001 · Cited by 38
“Minor changes in speech intensity can certainly have meaningful perceptual consequences, but it is important to consider that speech intensity measurement error is at least 2.5 dB (based on mouth-tomicrophone distance uncertainties and inherent error in sound-level meters; Švec & Granqvist, 2018).”
BackgroundInfluentialPhysical characterization of the milk chocolate using whey powder
Lapčíková, B., Lapčík, L., Salek, R. N., Valenta, T., Lorencová, E., & Vašina, M. (2021) · LWT · doi:10.1016/j.lwt.2021.112669 · Cited by 33
Mefferd, A. S., & Dietrich, M. S. (2020) · Journal of Speech Language and Hearing Research · doi:10.1044/2020_jslhr-19-00309 · Cited by 35
“During the recording of the calibration tone, the sound source was placed at the measured microphone-to-mouth distance away from the microphone and SPL meter (Ṧvec & Granqvist, 2018).”
MethodFeature Maps of the Acoustic Spectrum of the Voice
Pabon, P., & Ternström, S. (2018) · Journal of Voice · doi:10.1016/j.jvoice.2018.08.014 · Cited by 37
Quinn, S., Oates, J., & Dacakis, G. (2022) · Journal of Voice · doi:10.1016/j.jvoice.2022.03.001 · Cited by 40
Friction-induced interactions: acoustic emissions, vibrations, and wear – a multiscale review
Olejnik, P., & Desta, Y. D. (2025) · Nonlinear Dynamics · doi:10.1007/s11071-025-11397-5 · Cited by 28
“16 [81,86] typically set to 20 μ Pa in air [87,88].”
Mefferd, A. S., & Dietrich, M. S. (2019) · Journal of Speech Language and Hearing Research · doi:10.1044/2019_jslhr-s-msc18-18-0192 · Cited by 33
“A 1000-Hz calibration tone was recorded after each data collection using the participant’s microphone-to-mouth distance as the distance from the sound source to the microphone and SPL meter (Švec & Granqvist, 2018).”
MethodIbarra, E., Parra, J. A., Alzamendi, G. A., Cortés, J. P., Espinoza, V. M., Mehta, D. D., Hillman, R. E., & Zañartu, M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.732244 · Cited by 27
A Review of Acoustic Devices Based on Suspended 2D Materials and Their Composites
Wan, Z., Liu, H., Zheng, Y., Ma, Y., Liu, K., Zhou, X., Liu, C., Liu, K., & Wang, E. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202303519 · Cited by 24
Pommée, T., Balaguer, M., Mauclair, J., Pinquier, J., & Woisard, V. (2021) · Logopedics Phoniatrics Vocology · doi:10.1080/14015439.2020.1870245 · Cited by 29
A Cross-sectional Study of Perceptual and Acoustic Voice Characteristics in Healthy Aging
Schultz, B. G., Rojas, S., John, M. S., Kefalianos, E., & Vogel, A. P. (2021) · Journal of Voice · doi:10.1016/j.jvoice.2021.06.007 · Cited by 31
Glottal flow characteristics in vowels produced by speakers with heart failure
Mittapalle, K. R., Pohjalainen, H., Helkkula, P., Kaitue, K., Minkkinen, M., Tolppanen, H., Nieminen, T. V. M., & Alku, P. (2022) · Speech Communication · doi:10.1016/j.specom.2021.12.001 · Cited by 29
“The SPL was estimated using the approach described in Švec and Granqvist (2018) by comparing the average of the square of the speech waveform to that of the calibration tone (described in Section 2.1).”
MethodInfluentialSödersten, M., Oates, J., Sand, A., Granqvist, S., Quinn, S., Dacakis, G., & Nygren, U. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2024.02.003 · Cited by 25
Self-citationWhitfield, J. A., Kriegel, Z., Fullenkamp, A. M., & Mehta, D. D. (2019) · Journal of Speech Language and Hearing Research · doi:10.1044/2019_jslhr-s-msc18-18-0190 · Cited by 27
“These Praat-based intensities were adjusted by the difference between the Praat-based intensity and the SLM intensity to obtain an estimate of speech intensity in dB SPL. Calibration procedures aligned with Method 2A outlined by Švec and Granqvist (2018).”
MethodSpeech Treatment Effects on Narrative Intelligibility in French-Speaking Children With Dysarthria
Moya‐Galé, G., Keller, B., Escorial, S., & Levy, E. S. (2021) · Journal of Speech Language and Hearing Research · doi:10.1044/2020_jslhr-20-00258 · Cited by 21
“…PT = physical therapy was conducted at the beginning and end of each recording session to ensure the SPL level during presentation of the speech stimuli to listeners was representative of the child’s vocal intensity (Fox & Boliek, 2012; Levy et al., 2017; Ramig et al. 2001; Švec & Granqvist, 2018).”
BackgroundFlorencio, V. D. O., Almeida, A. A., Balata, P. M. M., Nascimento, S., Brockmann, M., & Lopes, L. W. (2021) · Journal of Voice · doi:10.1016/j.jvoice.2021.04.011 · Cited by 22
Whitfield, J. A., Holdosh, S. R., Kriegel, Z., Sullivan, L. E., & Fullenkamp, A. M. (2021) · Journal of Speech Language and Hearing Research · doi:10.1044/2020_jslhr-20-00264 · Cited by 24
Domestic cat larynges can produce purring frequencies without neural input
Herbst, C. T., Prigge, T., Garcia, M., Hampala, V., Hofer, R., Weissengruber, G. E., Švec, J. G., & Fitch, W. T. (2023) · Current Biology · doi:10.1016/j.cub.2023.09.014 · Cited by 18
“30 In order to assess the relative inter-cycle acoustic pressure variations within the subglottal tract, a second DPA 4061 microphone was positioned at a level of 15 cm below the vocal folds, aligned flush with the inside wall of the subglottal tract at a perpendicular angle to the subglottal airfow.”
Self-citationDaşdöğen, Ü., Awan, S. N., Bottalico, P., Iglesias, A., Getchell, N., & Abbott, K. V. (2023) · Journal of Voice · doi:10.1016/j.jvoice.2023.07.026 · Cited by 18
Toolkit to Examine Lifelike Language v.2.0: Optimizing Speech Biomarkers of Neurodegeneration
García, A. M., Ferrante, F. J., Pérez, G. N., Ponferrada, J., Welford, A. S., Pelella, N., Caccia, M., Belloli, L. M. L., Calcaterra, C., Santibáñez, C. G., et al. (2024) · Dementia and Geriatric Cognitive Disorders · doi:10.1159/000541581 · Cited by 26
“A solid wheel-less chair is recommended to prevent movement-related noise [42, 43].”
Marsano-Cornejo, M.-J., & Roco-Videla, Á. (2022) · Acta Otorrinolaringologica (English Edition) · doi:10.1016/j.otoeng.2022.10.004 · Cited by 13
Voice Maps as a Tool for Understanding and Dealing with Variability in the Voice
Ternström, S., & Pabon, P. (2022) · Applied Sciences · doi:10.3390/app122211353 · Cited by 13
Long, Y., Naghavi, P., Kojusner, B., Butler, K. R. B., Rampazzi, S., & Fu, K. E. (2023) · IEEE Symposium on Security and Privacy (S&P) · doi:10.1109/sp46215.2023.10179313 · Cited by 23
Lehoux, S., Hampala, V., & Švec, J. G. (2021) · Scientific Reports · doi:10.1038/s41598-020-79265-3 · Cited by 13
Self-citationPiezoelectric Ceramics with High d33 Constants and Their Application to Film Speakers
Kim, S. W., & Lee, H. C. (2021) · Materials · doi:10.3390/ma14195795 · Cited by 13
A Tutorial Review on Clinical Acoustic Markers in Speech Science
Schultz, B. G., & Vogel, A. P. (2022) · Journal of Speech Language and Hearing Research · doi:10.1044/2022_jslhr-21-00647 · Cited by 15
Quantifying vocal effort from the shape of the one-third octave long-term-average spectrum of speech
Liénard, J.-S. (2019) · The Journal of the Acoustical Society of America · doi:10.1121/1.5129677 · Cited by 19
Impact of Vocal Effort on Respiratory and Articulatory Kinematics
Abur, D., Perkell, J. S., & Stepp, C. E. (2021) · Journal of Speech Language and Hearing Research · doi:10.1044/2021_jslhr-21-00323 · Cited by 18
“The measurement error of speech intensity is thought to be at least 2.5 dB (based uncertainties in microphone distance and the inherent error of sound-level meters; Švec & Granqvist, 2018).”
BackgroundInfluentialFlow-induced oscillations of vocal-fold replicas with tuned extensibility and material properties
Luizard, P., Bailly, L., Yousefi-Mashouf, H., Girault, R., Orgéas, L., & Bernardoni, N. H. (2023) · Scientific Reports · doi:10.1038/s41598-023-48080-x · Cited by 19
“Subglottal pressure for hydrogel and sound pressure level for all materials are comparable with previous research based on artificial vocal folds 11 as well as excised larynges 2,92,95,97 .”
BackgroundMethodThe Pediatric Vocal Mechanism: Structure and Function
Fujiki, R. B., Venkatraman, A., & Murray, E. S. H. (2025) · Journal of Voice · doi:10.1016/j.jvoice.2025.03.025 · Cited by 14
Carl, M., Levy, E. S., & Icht, M. (2022) · International Journal of Language & Communication Disorders · doi:10.1111/1460-6984.12715 · Cited by 14
Lehoux, S., Popeil, L., & Švec, J. G. (2022) · Journal of Voice · doi:10.1016/j.jvoice.2022.02.014 · Cited by 23
Self-citationMultisensory biofeedback: Promoting the recessive somatosensory control in operatic singing pedagogy
Angelakis, E., Andreopoulou, A., & Georgaki, A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102400 · Cited by 11
Validation of the Acoustic Voice Quality Index Version 03.01 in Turkish
Yeşilli-Puzella, G., Maryn, Y., Tunçer, A. M., Akbulut, S., Ünsal, E. M., & Özkan, E. T. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2024.08.030 · Cited by 12
Evaluating a Vibratory Positive Expiratory Pressure (PEP) Device as a Dysphonia Treatment
Saccente‐Kennedy, B., Andrade, P. A., & Epstein, R. (2022) · Journal of Voice · doi:10.1016/j.jvoice.2022.09.026 · Cited by 9
Noise in ICUs: Review and Detailed Analysis of Long-Term SPL Monitoring in ICUs in Northern Spain
Althahab, A. Q. J., Vuksanović, B., Al‐Mosawi, M., Machimbarrena, M., & Arias, R. (2022) · Sensors · doi:10.3390/s22239038 · Cited by 9
AVID: A speech database for machine learning studies on vocal intensity
Alku, P., Kodali, M., Laaksonen, L., & Kadiri, S. R. (2024) · Speech Communication · doi:10.1016/j.specom.2024.103039 · Cited by 18
Evidence-Based Recommendations for Tablet Recordings From the Bridge2AI-Voice Acoustic Experiments
Awan, S. N., Bahr, R. H., Watts, S., Boyer, M., Budinsky, R., & Bensoussan, Y. E. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2024.08.029 · Cited by 8
Dwenger, K., Roy, N., Jennings, S. G., Smith, M. E., Mathy, P., Simonyan, K., & Barkmeier‐Kraemer, J. M. (2025) · Journal of Speech Language and Hearing Research · doi:10.1044/2024_jslhr-24-00476 · Cited by 8
“Sound pressure level (SPL) measure calibration for voice recordings acquired using head-mounted microphones was conducted to enable comparable acoustic measures of voice intensity between speakers ( Š vec & Granqvist, 2010, 2018).”
InfluentialKovacs, S., & Darling-White, M. (2022) · Journal of Speech Language and Hearing Research · doi:10.1044/2022_jslhr-22-00295 · Cited by 8
Do-It-Yourself Voice Dosimeter Device: A Tutorial and Performance Results
Bottalico, P., & Nudelman, C. J. (2023) · Journal of Speech Language and Hearing Research · doi:10.1044/2023_jslhr-23-00060 · Cited by 8
Effects of Historical Recording Technology on Vibrato in Modern-Day Opera Singers
Glasner, J. D., & Johnson, A. M. (2020) · Journal of Voice · doi:10.1016/j.jvoice.2020.07.022 · Cited by 8
Holmberg, J., Södersten, M., Linander, I., & Nylén, F. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2024.07.034 · Cited by 7
Zhou, X. (2024) · Entertainment Computing · doi:10.1016/j.entcom.2024.100782 · Cited by 8
Lã, F. M. B., Sundberg, J., & Granqvist, S. (2021) · Psychology of Music · doi:10.1177/03057356211026735 · Cited by 6
“This allowed recalibration to a 30 cm mouth-to-microphone distance using the equation SPL log d @30 20 10 30 1cm = × (1) where d1 is the mouth-to-microphone distance (Švec & Granqvist, 2018).”
Self-citationArias‐Vergara, T., Batliner, A. M., Rader, T., Polterauer, D., Högerle, C., Müller, J., Orozco‐Arroyave, J. R., Nöth, E., & Schuster, M. E. (2022) · Journal of Speech Language and Hearing Research · doi:10.1044/2022_jslhr-21-00116 · Cited by 12
“In the case of loudness, the sound pressure is considered to measure the amount of acoustic energy produced by a speaker ( Š vec & Granqvist, 2018 where p 0 is the reference sound pressure of the air expressed in Pascal ( p 0 = 20 μ Pa) and p is the sound pressure computed as the root-mean-square…”
It Sounds like It Feels: Preliminary Exploration of an Aeroacoustic Diagnostic Protocol for Singers
Baker, C. P., Purdy, S. C., Rakena, T. O., & Bonnini, S. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12155130 · Cited by 7
“The trimmed acoustic signal was imported into Sopran [30] and calibrated with respect to SPL using the calibration tone collected at the time of recording [62].”
MethodEstimating urban noise levels from Multi-Scale and Multi-Spectral remote sensing imagery
Chen, Z., Fei, T., Xiao, J., Huang, J., Jia, D. K., & Bian, M. (2025) · International Journal of Applied Earth Observation and Geoinformation · doi:10.1016/j.jag.2025.104818 · Cited by 6
An End-to-End Overview of Clinical Speech AI
Ng, S.-I., Xu, L., Siegert, I., Cummins, N., Benway, N. R., Liss, J., & Berisha, V. (2026) · IEEE Transactions on Audio Speech and Language Processing · doi:10.1109/taslpro.2026.3660470 · Cited by 13
“To mitigate this, clinical label collection should be informed by guidance documents from professional organizations [121], [244], [245].”
Measuring speaking rate: how do objective measurements correlate with audio-perceptual ratings?
Iwarsson, J., Næs, J., & Hollen, R. (2021) · Logopedics Phoniatrics Vocology · doi:10.1080/14015439.2021.1988702 · Cited by 6
Rodrigues, V. N., Andriollo, D. B., & Cielo, C. A. (2022) · Journal of Voice · doi:10.1016/j.jvoice.2022.11.013 · Cited by 6
Acoustic cues to femininity and masculinity in spontaneous speech
Nylén, F., Holmberg, J., & Södersten, M. (2024) · The Journal of the Acoustical Society of America · doi:10.1121/10.0025932 · Cited by 6
Exploring Emotion and Emotional Variability as DigitalBiomarkers in Frontotemporal Dementia Speech
Gong, Y., Parllaku, F., Placek, K., Vilela, M., Harel, B., Simen, A. A., Subirana, B., Brodtmann, A. G., Vogel, A. P., & Tracey, B. (2024) · IEEE Access · doi:10.1109/access.2024.3402999 · Cited by 8
“Participants provided informed consent and were seated in a sound-attenuated room (ambient noise in audio files <50dB A ; M = 36.5dB A , SD = 1.27) [49].”
MethodInfluentialMarsano-Cornejo, M.-J., Roco-Videla, Á., Capona-Corbalán, D., & Silva-Harthey, C. (2020) · Acta Otorrinolaringológica Española · doi:10.1016/j.otorri.2020.04.007 · Cited by 6
Matvejeff, A. T., Silvonen, V., Heikkilä, P., Sanmark, E., Hakala, J. P., Kuittinen, N., Geneid, A., Laukkanen, A.-M., Alku, P., Oksanen, L., et al. (2025) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2025.106619 · Cited by 6
Robust Textile‐Based Electromagnetic Audio Interfaces
Guan, X., Lan, T., Zhao, D., Liu, Z., Zhang, K., Zhou, Y., Zhao, Y., Pi, Y., Lu, C., Yu, H., et al. (2025) · Advanced Materials · doi:10.1002/adma.202508022 · Cited by 6
Multi‐speaker experimental designs: Methodological considerations
Offrede, T., Fuchs, S. I., & Mooshammer, C. R. (2021) · Language and Linguistics Compass · doi:10.1111/lnc3.12443 · Cited by 8
“For further technical recommendations concerning types of microphones, see Švec and Granqvist (2010), and for considerations about microphone calibration, see Švec and Granqvist (2018).”
BackgroundJapanese macaque phonatory physiology
Herbst, C. T., Koda, H., Kunieda, T., Suzuki, J., Garcia, M., Fitch, W. T., & Nishimura, T. (2018) · Journal of Experimental Biology · doi:10.1242/jeb.171801 · Cited by 5
Long-Term Average Spectrum Characteristics of Portuguese Fado-Canção from Coimbra
Lã, F. M. B., Silva, L. S., & Granqvist, S. (2021) · Journal of Voice · doi:10.1016/j.jvoice.2021.03.005 · Cited by 5
Self-citationPara uma modelagem das formas prosódicas dos Marcadores Discursivos
Raso, T., Rilliard, A. O. B., & Santos, S. M. (2022) · Domínios de Lingu gem · doi:10.14393/dl52-v16n4a2022-8 · Cited by 5
Differences in nasalance scores obtained with different Nasometer headsets
Bressmann, T., & Tang, B. H. Y. (2024) · Clinical Linguistics & Phonetics · doi:10.1080/02699206.2024.2305118 · Cited by 5
“The distance law states that the SPL measurements increase by 6 dB when the distance between the mouth/nose and the microphone is halved (Švec & Granqvist, 2018).”
Kratz, E., Scheffer, J., Volc, D., & Seebacher, B. (2025) · BMC Neurology · doi:10.1186/s12883-025-04161-0 · Cited by 5
“Calibration was performed using sustained ‘Ah’ vowels over ≥ 4 s following recommended procedures [34] and guidelines [35], with each recording including a reference reading from the sound level meter, recorded on an A-weighted scale [34].”
Maryn, Y., Dwenger, K., Kaufmann, S., & Barkmeier‐Kraemer, J. M. (2025) · Journal of Speech Language and Hearing Research · doi:10.1044/2025_jslhr-24-00467 · Cited by 6
“Speech sounds were captured with an AKG C520 head-mounted condenser microphone positioned at ~5 cm from the mouth and at an azimuthal angle of circa 45°, in accordance to Titze and Winholtz (1993) and Š vec and Granqvist (2010, 2018).”
Relation between Orotracheal Intubation, Inflammatory Markers, Breathing and Voice in Post-COVID-19
Feltrin, T. D., Cielo, C. A., & Pasqualoto, A. S. (2023) · Journal of Voice · doi:10.1016/j.jvoice.2023.02.015 · Cited by 6
“All MPT emissions were collected twice in a place with ambient noise lower than 48 dBC, measured by a digital sound pressure level meter (Icel, DL 4200) ((36,37)).”
Ceylan, M. E., Cangï, M. E., Yılmaz, G., Peru, B. S., & Yiğit, Ö. (2023) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-023-08179-3 · Cited by 7
“However, it has also been reported that it is difficult to obtain the specified noise levels for recordings to be made at a distance of 30 cm in clinical and hospital conditions [24].”
BackgroundPassing rail traffic reduces bat activity
Jerem, P., & Mathews, F. (2021) · Scientific Reports · doi:10.1038/s41598-021-00101-3 · Cited by 8
Camargo, D. A., Munis, R. A., Miyajima, R. H., Lima, R. C. A., & Simões, D. (2022) · International Journal of Forest Engineering · doi:10.1080/14942119.2022.2083048 · Cited by 4
“The sound pressure level (SPL) was estimated according to Švec and Granqvist (2018), corresponding to the effect of sound on the operators’ auditory threshold (Equation 1).”
MethodCamargo, D. A., Munis, R. A., Rocha, Q. S., & Simões, D. (2022) · Australian Forestry · doi:10.1080/00049158.2022.2099121 · Cited by 4
“…obtained every 60 s, with adjustment of the calibration curve A to simulate the capture of the human ear in the range of 70–140 dB(A), in line with Švec and Granqvist (2018), SPL ¼ 20 log P P0 � � (1) where P is the sound pressure being measured and P0 is the reference sound pressure…”
MethodA Simple Method to Obtain Basic Acoustic Measures From Video Recordings as Subtitles
Kumar, S. P., & Švec, J. G. (2018) · Journal of Speech Language and Hearing Research · doi:10.1044/2018_jslhr-s-17-0472 · Cited by 3
Self-citationLins, M. N. B., Pereira, L. M. D. A., & Masson, M. L. V. (2020) · Revista Brasileira de Saúde Ocupacional · doi:10.1590/2317-6369000027518 · Cited by 3
A study to translate and validate the Thai version of the Victoria Respiratory Congestion Scale
Tantiwatniyom, T., & Nagaviroj, K. (2022) · BMC Palliative Care · doi:10.1186/s12904-022-01043-x · Cited by 3
“Despite the fact that we followed the standard sound measurement protocol, including the use of an IEC 61,672 class 2 sound meter and measuring techniques recommended by the Speech Sound Level Measurement Guidelines [8].”
MethodBaker, C. P., Sundberg, J., Purdy, S. C., & Rakena, T. O. (2022) · Logopedics Phoniatrics Vocology · doi:10.1080/14015439.2022.2140455 · Cited by 7
“All signal intensity data were adjusted to reflect the standard 30 cm microphone distance using the equation L @ 7cm (cid:0) 20 � log 10 (7/30), where L @ 7cm is the dB level at the original 7 cm microphone-to-mouth distance [82].”
MethodThe intensities of vowels and plosive bursts and their impact on text intelligibility in singing
Vurma, A., Meister, E., Meister, L., Ross, J., Raju, M., Kala, V., & Dede, T. (2023) · The Journal of the Acoustical Society of America · doi:10.1121/10.0021968 · Cited by 3
Classical singers are also proficient in non-classical singing
Bruder, C., & Larrouy-Maestri, P. (2023) · Frontiers in Psychology · doi:10.3389/fpsyg.2023.1215370 · Cited by 3
Altered Auditory Feedback in Teachers: A Preliminary Investigation
Nudelman, C. J., Flaherty, M. M., & Bottalico, P. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2024.10.015 · Cited by 3
Carrillo-González, A., Atará-Piraquive, Á. P., Camargo-Mendoza, M., Hernández-Contreras, J. R., & Cantor-Cutiva, L. C. (2024) · Revista de Investigación e Innovación en Ciencias de la Salud · doi:10.46634/riics.333 · Cited by 4
Marsano-Cornejo, M.-J., Roco-Videla, Á., Capona-Corbalán, D., & Silva-Harthey, C. (2021) · Acta Otorrinolaringologica (English Edition) · doi:10.1016/j.otoeng.2020.04.004 · Cited by 3
Manes, J. L., Herschel, E., Aveni, K., Tjaden, K., Parrish, T. B., Simuni, T., Corcos, D. M., & Roberts, A. (2021) · Journal of Communication Disorders · doi:10.1016/j.jcomdis.2021.106149 · Cited by 4
Analysis of The Noise Level of The Diesel Engine with 1100 RPM in The Indoor Condition
Qosim, N. (2022) · Journal of Applied Engineering and Technological Science (JAETS) · doi:10.37385/jaets.v3i2.406 · Cited by 3
Cruz, T. L. B., Frič, M., & Andrade, P. A. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2024.03.033 · Cited by 2
Darling-White, M., & McHugh, A. (2024) · American Journal of Speech-Language Pathology · doi:10.1044/2024_ajslp-24-00248 · Cited by 3
Yılmaz, G., Konrot, A. K., Keleş, M. S., KILIÇ, M. A., Özgeriş, F. B., & Keleş, P. (2025) · Journal of Voice · doi:10.1016/j.jvoice.2025.04.029 · Cited by 2
Pestana, P. M., Alegria, R. F. D. G., Araújo, A., Melo, C., Brasil, C. C. P., Byrne, A., & Manso, M. C. (2025) · Journal of Voice · doi:10.1016/j.jvoice.2025.06.002 · Cited by 4
Kodali, M., Ansari, L., Kadiri, S. R., Narayanan, S. S., & Alku, P. (2025) · Speech Communication · doi:10.1016/j.specom.2025.103288 · Cited by 5
Sex and Age Stratified Voice Data in Japanese Vocally Healthy Individuals: Vocal Capacity
Yamauchi, A., Imagawa, H., Yokonishi, H., Sakakibara, K., & Tayama, N. (2022) · Journal of Voice · doi:10.1016/j.jvoice.2022.03.027 · Cited by 2
Marsano-Cornejo, M.-J., & Roco-Videla, Á. (2022) · Acta Otorrinolaringológica Española · doi:10.1016/j.otorri.2022.06.003 · Cited by 2
Impact of Face Masks on Speech in Parkinson's Disease: Effect of Clear and Loud Speech Styles
Knowles, T., & Badh, G. (2023) · Journal of Speech Language and Hearing Research · doi:10.1044/2022_jslhr-22-00291 · Cited by 3
Audible Inhalation as a Practice for Mitigating Systemic Turn-Taking Troubles: A Conjecture
Robinson, J. D. (2023) · Research on Language and Social Interaction · doi:10.1080/08351813.2023.2205306 · Cited by 2
“Admittedly, this goal may not have been achieved, given how acoustics are affected by sound-pressure level (SPL; Švec & Granqvist, 2018).”
BackgroundVocal Fold Dissipated Power in Females with Hyperfunctional Voice Disorders
Ghasemzadeh, H., Hillman, R. E., Espinoza, V. M., Erath, B. D., & Mehta, D. D. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2024.09.039 · Cited by 4
Pilsl, T., Köberlein, M. C., Kirsch, J., Doellinger, M., & Echternach, M. (2025) · Journal of Speech Language and Hearing Research · doi:10.1044/2024_jslhr-24-00474 · Cited by 2
Speech Range Profile Data in German-Speaking Adults With Vox Phonetography
Lübke, C.-S., Binkofski, F., & Latoszek, B. B. V. (2025) · Journal of Voice · doi:10.1016/j.jvoice.2025.02.002 · Cited by 2
SPRAAKLAB - mobile laboratory for speech recorded acoustically and kinematically
Rebernik, T., Jacobi, J., Buurke, R. S. S. J., Tienkamp, T. B., Abur, D., & Wieling, M. B. (2025) · Behavior Research Methods · doi:10.3758/s13428-025-02726-y · Cited by 4
“We then calculated the SNR using the following formula (see also Svec & Granqvist, 2018): HNR is a measure that compares period and non-periodic (i.e., harmonic and noisy) components of a speech signal.”
Daşdöğen, Ü., Awan, S. N., Koiler, R., Getchell, N., Roth, D. F., & Verdolini-Abbott, K. (2025) · Journal of Voice · doi:10.1016/j.jvoice.2025.06.013 · Cited by 2
Metadata
- Authors
- Švec, J. G., & Granqvist, S.
- Affiliations
- Palacký University Olomouc (CZ)
- Karolinska Institutet (SE)
- Venue
- Journal of Speech, Language, and Hearing Research
- Published
- 2018-03-15
- Volume
- 61
- Issue
- 3
- Pages
- 441-461
- ISSN
- 1092-4388 (ISSN-L)
- 1558-9102
- OpenAlex
- W2787946070
- Semantic Scholar
- 1e585efdf9a3ca320cc88ffc3d3faadd0cd08ac3
- Cited by
- 166
- References
- 35
- Citations by year
- 2026: 20 · 2025: 36 · 2024: 24 · 2023: 22 · 2022: 23 · 2021: 25 · 2020: 7 · 2019: 4 · 2018: 5
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Speech Language and Hearing Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Speech and Hearing › Voice and Speech Disorders
- Physical Sciences › Computer Science › Signal Processing › Speech and Audio Processing
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Phonetics and Phonology Research
- Keywords
- sound pressure level, voice, speech, sound level meter, microphone calibration, head-mounted microphone, frequency weighting, time weighting, background noise, measurement reproducibility
- MeSH terms
- Pressure, Speech, Speech Production Measurement, Voice, Practice Guidelines as Topic, Electrical Equipment and Supplies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.