Evaluation of Acoustic Analyses of Voice in Nonoptimized Conditions
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objectives: This study aimed to evaluate the fidelity and accuracy of a smartphone microphone and recording environment on acoustic measurements of voice. Method: A prospective cohort proof-of-concept study. Two sets of prerecorded samples (a) sustained vowels (/a/) and (b) Rainbow Passage sentence were played for recording via the internal iPhone microphone and the Blue Yeti USB microphone in two recording environments: a sound-treated booth and quiet office setting. Recordings were presented using a calibrated mannequin speaker with a fixed signal intensity (69 dBA), at a fixed distance (15 in.). Each set of recordings (iPhone—audio booth, Blue Yeti—audio booth, iPhone—office, and Blue Yeti—office), was time-windowed to ensure the same signal was evaluated for each condition. Acoustic measures of voice including fundamental frequency ( f o ), jitter, shimmer, harmonic-to-noise ratio (HNR), and cepstral peak prominence (CPP), were generated using a widely used analysis program (Praat Version 6.0.50). The data gathered were compared using a repeated measures analysis of variance. Two separate data sets were used. The set of vowel samples included both pathologic ( n = 10) and normal ( n = 10), male ( n = 5) and female ( n = 15) speakers. The set of sentence stimuli ranged in perceived voice quality from normal to severely disordered with an equal number of male ( n = 12) and female ( n = 12) speakers evaluated. Results: The vowel analyses indicated that the jitter, shimmer, HNR, and CPP were significantly different based on microphone choice and shimmer, HNR, and CPP were significantly different based on the recording environment. Analysis of sentences revealed a statistically significant impact of recording environment and microphone type on HNR and CPP. While statistically significant, the differences across the experimental conditions for a subset of the acoustic measures (viz., jitter and CPP) have shown differences that fell within their respective normative ranges. Conclusions: Both microphone and recording setting resulted in significant differences across several acoustic measurements. However, a subset of the acoustic measures that were statistically significant across the recording conditions showed small overall differences that are unlikely to have clinical significance in interpretation. For these acoustic measures, the present data suggest that, although a sound-treated setting is ideal for voice sample collection, a smartphone microphone can capture acceptable recordings for acoustic signal analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The emerging field of mobile health
Steinhubl, S. R., Muse, E. D., & Topol, E. J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa3487 · Cited by 822
Adverse Effects of Environmental Noise on Acoustic Voice Quality Measurements
Deliyski, D. D., Shaw, H. S., & Evans, M. K. (2005) · Journal of Voice · doi:10.1016/j.jvoice.2004.07.003 · Cited by 199
Guidi, A., Salvi, S., Ottaviano, M., Gentili, C., Bertschy, G., De Rossi, D., Scilingo, E., & Vanello, N. (2015) · Sensors · doi:10.3390/s151128070 · Cited by 46
Cited by
Developing an Artificial Intelligence Tool to Predict Vocal Cord Pathology in Primary Care Settings
Compton, E. C., Cruz, T., Andreassen, M., Beveridge, S., Bosch, D., Randall, D. R., & Livingstone, D. (2023) · The Laryngoscope · doi:10.1002/lary.30432 · Cited by 38
Characterization of Primary Muscle Tension Dysphonia Using Acoustic and Aerodynamic Voice Metrics
Shembel, A. C., Lee, J., Sacher, J. R., & Johnson, A. M. (2023) · Journal of Voice · doi:10.1016/j.jvoice.2021.05.019 · Cited by 27
Interpreting pretrained speech models for automatic speech assessment of voice disorders
Lau, H. S., Huntly, M., Morgan, N., Iyenoma, A., Zeng, B., & Bashford, T. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-67278-1_5 · Cited by 2
Metadata
- Authors
- van der Woerd, B., Wu, M., Parsa, V., Doyle, P. C., & Fung, K.
- Venue
- Journal of Speech, Language, and Hearing Research
- Published
- 2020-12-14
- Volume
- 63
- Issue
- 12
- Pages
- 3991-3999
- ISSN
- 1092-4388 (ISSN-L)
- 1558-9102
- OpenAlex
- W3100166103
- Cited by
- 38
- References
- 3
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Acoustic Analyses of Voice in Nonoptimized Conditions. https://app.cochat.ai/papers/10.1044/2020_jslhr-20-00212
- The paper
- van der Woerd, B., Wu, M., Parsa, V., Doyle, P. C., & Fung, K. (2020). Evaluation of Acoustic Analyses of Voice in Nonoptimized Conditions. Journal of Speech, Language, and Hearing Research. https://doi.org/10.1044/2020_jslhr-20-00212
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.