CoChat

Evaluation of Acoustic Analyses of Voice in Nonoptimized Conditions

van der Woerd, Benjamin, Wu, Min, Parsa, Vijay, Doyle, Philip C., Fung, Kevin · 2020 · Journal of Speech, Language, and Hearing Research
Cited by 38

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objectives: This study aimed to evaluate the fidelity and accuracy of a smartphone microphone and recording environment on acoustic measurements of voice. Method: A prospective cohort proof-of-concept study. Two sets of prerecorded samples (a) sustained vowels (/a/) and (b) Rainbow Passage sentence were played for recording via the internal iPhone microphone and the Blue Yeti USB microphone in two recording environments: a sound-treated booth and quiet office setting. Recordings were presented using a calibrated mannequin speaker with a fixed signal intensity (69 dBA), at a fixed distance (15 in.). Each set of recordings (iPhone—audio booth, Blue Yeti—audio booth, iPhone—office, and Blue Yeti—office), was time-windowed to ensure the same signal was evaluated for each condition. Acoustic measures of voice including fundamental frequency ( f o ), jitter, shimmer, harmonic-to-noise ratio (HNR), and cepstral peak prominence (CPP), were generated using a widely used analysis program (Praat Version 6.0.50). The data gathered were compared using a repeated measures analysis of variance. Two separate data sets were used. The set of vowel samples included both pathologic ( n = 10) and normal ( n = 10), male ( n = 5) and female ( n = 15) speakers. The set of sentence stimuli ranged in perceived voice quality from normal to severely disordered with an equal number of male ( n = 12) and female ( n = 12) speakers evaluated. Results: The vowel analyses indicated that the jitter, shimmer, HNR, and CPP were significantly different based on microphone choice and shimmer, HNR, and CPP were significantly different based on the recording environment. Analysis of sentences revealed a statistically significant impact of recording environment and microphone type on HNR and CPP. While statistically significant, the differences across the experimental conditions for a subset of the acoustic measures (viz., jitter and CPP) have shown differences that fell within their respective normative ranges. Conclusions: Both microphone and recording setting resulted in significant differences across several acoustic measurements. However, a subset of the acoustic measures that were statistically significant across the recording conditions showed small overall differences that are unlikely to have clinical significance in interpretation. For these acoustic measures, the present data suggest that, although a sound-treated setting is ideal for voice sample collection, a smartphone microphone can capture acceptable recordings for acoustic signal analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1044/2020_jslhr-20-00212

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 38

Metadata

Authors
van der Woerd, B., Wu, M., Parsa, V., Doyle, P. C., & Fung, K.
Venue
Journal of Speech, Language, and Hearing Research
Published
2020-12-14
Volume
63
Issue
12
Pages
3991-3999
ISSN
  • 1092-4388 (ISSN-L)
  • 1558-9102
OpenAlex
W3100166103
Cited by
38
References
3
FWCI
2.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Acoustic Analyses of Voice in Nonoptimized Conditions. https://app.cochat.ai/papers/10.1044/2020_jslhr-20-00212
The paper
van der Woerd, B., Wu, M., Parsa, V., Doyle, P. C., & Fung, K. (2020). Evaluation of Acoustic Analyses of Voice in Nonoptimized Conditions. Journal of Speech, Language, and Hearing Research. https://doi.org/10.1044/2020_jslhr-20-00212

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.