The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Comparing Internal and External Standards in Voice Quality Judgments
Abstract
A new descriptive framework for voice quality perception (Kreiman, Gerratt, Kempster, Erman, & Berke, 1993) states that when listeners rate a voice on some quality dimension (e.g., roughness), they compare the stimulus presented to an internal standard or scale. Hypothetically, substituting explicit, external standards for these unstable internal standards should improve listener reliability. Further, the framework suggests that internal standards for vocal qualities are inherently unstable, and may be influenced by factors other than the physical signal being judged. Among these factors, context effects may cause drift in listeners’ voice ratings by influencing the internal standard against which judgments are made. To test these hypotheses, we asked 12 clinicians to judge the roughness of 22 synthetic stimuli using two scales: a traditional 5-point equal-appearing interval (EAI) scale and a scale with explicit anchor stimuli for each scale point. The stimulus set included a relatively large number of normal and mildly rough voices. We predicted that this would produce an increase in the perceived roughness of moderately rough stimuli over time for the EAI ratings, but not for the explicitly anchored ratings. Ratings made using the anchored scale were significantly more reliable than those gathered using the unanchored paradigm. Further, as predicted, ratings on the unanchored EAI scale drifted significantly within a listening session in the direction expected, but ratings on the anchored scale did not. These results are consistent with our framework and suggest that explicitly anchored paradigms for voice quality evaluation might improve both research and clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Estimation of the reliability of ratings.
Ebel, R. L. (1951) · Psychometrika · doi:10.1007/bf02288803 · Cited by 976
Cited by
The Effect of Perceptual Training on Inexperienced Listeners' Judgments of Dysphonic Voice
Eadie, T. L., & Baylor, C. R. (2006) · Journal of Voice · doi:10.1016/j.jvoice.2005.08.007 · Cited by 254
Cordes, A. K., & Ingham, R. J. (1994) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jshr.3702.279 · Cited by 104
Pathological assessment of patients’ speech signals using nonlinear dynamical analysis
Vaziri, G., Almasganj, F., & Behroozmand, R. (2010) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.10.011 · Cited by 88
Kim, Y., & Choi, Y. (2017) · Journal of Speech Language and Hearing Research · doi:10.1044/2017_jslhr-s-16-0121 · Cited by 44
Narasimhan, S., & Rashmi, R. (2022) · Journal of Voice · doi:10.1016/j.jvoice.2020.06.009 · Cited by 38
Metadata
- Authors
- Gerratt, B. R., Kreiman, J., Antonanzas-Barroso, N., & Berke, G. S.
- Venue
- Journal of Speech, Language, and Hearing Research
- Published
- 1993-02
- Volume
- 36
- Issue
- 1
- Pages
- 14-20
- ISSN
- 1092-4388 (ISSN-L)
- 1558-9102
- OpenAlex
- W2048484272
- Cited by
- 280
- References
- 2
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparing Internal and External Standards in Voice Quality Judgments. https://app.cochat.ai/papers/10.1044/jshr.3601.14
- The paper
- Gerratt, B. R., Kreiman, J., Antonanzas-Barroso, N., & Berke, G. S. (1993). Comparing Internal and External Standards in Voice Quality Judgments. Journal of Speech, Language, and Hearing Research. https://doi.org/10.1044/jshr.3601.14
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.