Comparisons Among Aerodynamic, Electroglottographic, and Acoustic Spectral Measures of Female Voice
Abstract
This study examines measures of the glottal airflow waveform, the electroglottographic signal (EGG), amplitude differences between peaks in the acoustic spectrum, and observations of the spectral energy content of the third formant (F3), in terms of how they relate to one another. Twenty females with normal voices served as subjects. Both group and individual data were studied. Measurements were made for the vowel in two speech tasks: strings of the syllable /pæ/ and sustained phonation of /æ/, which were produced at two levels of vocal effort: comfortable and loud voice. The main results were: 1. Significant differences in parameter values between /pæ/ and /æ/ were related to significant differences in the sound pressure level (SPL). 2. An “adduction quotient,” measured from the glottal waveform at a 30% criterion, was sensitive enough to differentiate between waveforms reflecting abrupt versus gradual vocal fold closing movements. 3. DC flow showed weak or nonsignificant relationships with acoustic measures. 4. The spectral content in the third formant (F3) in comfortable loudness typically consisted of a mix of noise and harmonic energy. In loud voice, the F3 spectral content typically consisted of harmonic energy. 5. Significant differences were found in all measures between tokens with F3 harmonic energy and tokens with F3 noise, independent of loudness condition. 6. Strong relationships between flow- and EGG-adduction quotients suggested that these signals can be used to complement each other. 7. The amplitude difference between spectral peaks of the first and third formant (F1-F3) was found to add information about abruptness of airflow decrease (flow declination) that may be lost in the glottal waveform signal due to low-pass filtering. The results are discussed in terms of how an integrated use of these measures can contribute to a better understanding of the normal vocal mechanism and help to improve methods for evaluating vocal function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Patel, R. R., Awan, S. N., Barkmeier-Kraemer, J., Courey, M., Deliyski, D., Eadie, T., Paul, D., Švec, J. G., & Hillman, R. (2018) · American Journal of Speech-Language Pathology · doi:10.1044/2018_ajslp-17-0009 · Cited by 818
Self-citationPhonation types: a cross-linguistic overview
Gordon, M., & Ladefoged, P. (2001) · Journal of Phonetics · doi:10.1006/jpho.2001.0147 · Cited by 678
Glottal characteristics of female speakers: Acoustic correlates
Hanson, H. M. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.417991 · Cited by 376
Acoustic effects of variation in vocal effort by men, women, and children
Traunmüller, H., & Eriksson, A. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.429414 · Cited by 312
Lee, J. B., & Lee, H. G. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106014 · Cited by 15
Metadata
- Authors
- Holmberg, E. B., Hillman, R. E., Perkell, J. S., Guiod, P. C., & Goldman, S. L.
- Venue
- Journal of Speech, Language, and Hearing Research
- Published
- 1995-12
- Volume
- 38
- Issue
- 6
- Pages
- 1212-1223
- ISSN
- 1092-4388 (ISSN-L)
- 1558-9102
- OpenAlex
- W2029308246
- Cited by
- 203
- References
- 0
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparisons Among Aerodynamic, Electroglottographic, and Acoustic Spectral Measures of Female Voice. https://app.cochat.ai/papers/10.1044/jshr.3806.1212
- The paper
- Holmberg, E. B., Hillman, R. E., Perkell, J. S., Guiod, P. C., & Goldman, S. L. (1995). Comparisons Among Aerodynamic, Electroglottographic, and Acoustic Spectral Measures of Female Voice. Journal of Speech, Language, and Hearing Research. https://doi.org/10.1044/jshr.3806.1212
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.