Recommendations for standards of monitoring during anaesthesia and recovery
Open accessAbstract
I have just received the revised Recommendations for Standards of Monitoring during Anaesthesia and Recovery [1], which contains a number of sensible changes from the previous edition. However, I must take issue with the suggestion that a vapour analyser is an essential (rather than desirable) monitor for the maintenance of anaesthesia in all circumstances with the implication that the absence of such a monitor is medicolegally indefensible in the event of a civil claim. Many hospitals employ circle breathing systems for the maintenance of anaesthesia, and I agree that it is appropriate to monitor vapour concentrations in such systems, particularly if low fresh gas flows are utilised. However, I am sure that there are nationally a significant number of locations where high fresh gas flow non-circle anaesthesia systems are used for the maintenance of anaesthesia, where no vapour analyser has been installed. Presumably, the main concern in this situation is that the vaporiser will run out of anaesthetic agent unnoticed or that there is a leak of fresh gas around a poorly seated vaporiser. Checking the vaporiser regularly during the conduct of general anaesthesia is part of every anaesthetist's routine. I do not see how the presence of a vapour analyser in the non-circle anaesthesia system is of equal importance medicolegally as a pulse oximeter, blood pressure monitor, electrocardiograph or capnograph during the maintenance of anaesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Postoperative pulmonary complications
Miskovic, A., & Lumb, A. B. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex002 · Cited by 1,123
Guidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
Klein, A. A., Meek, T., Allcock, E., Cook, T. M., Mincher, N., Morris, C., Nimmo, A. F., Pandit, J. J., Pawa, A., Rodney, G., et al. (2021) · Anaesthesia · doi:10.1111/anae.15501 · Cited by 340
Party, M. O. T. W., Griffiths, R., Alper, J., Beckingsale, A., Goldhill, D., Heyburn, G., Holloway, J., Leaper, E., Parker, M., Ridgway, S., et al. (2012) · Anaesthesia · doi:10.1111/j.1365-2044.2011.06957.x · Cited by 278
Sultan, P., Habib, A. S., Cho, Y., & Carvalho, B. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev325 · Cited by 108
Metadata
- Authors
- Mitchell, J.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2001-05-02
- Volume
- 56
- Issue
- 5
- Pages
- 488-488
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W1988448947
- Cited by
- 206
- References
- 0
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recommendations for standards of monitoring during anaesthesia and recovery. https://app.cochat.ai/papers/10.1046/j.1365-2044.2001.02047-7.x
- The paper
- Mitchell, J. (2001). Recommendations for standards of monitoring during anaesthesia and recovery. Anaesthesia. https://doi.org/10.1046/j.1365-2044.2001.02047-7.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.