Near-infrared spectroscopy grades the severity of intermittent claudication in diabetics more accurately than ankle pressure measurement
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: The aim of this study was to evaluate near-infrared spectroscopy (NIRS), combined with a treadmill-walking test, as a method of assessment of intermittent claudication (IC) in diabetic patients. Methods: Some 208 symptomatic legs in 153 consecutive patients who complained of calf IC due to atherosclerotic disease were studied with NIRS and resting ankle: brachial pressure index (ABPI). Results: There was good reproducibility of NIRS measurements. Three distinct types of IC were detected by NIRS. ABPI was significantly different between these three types in non-diabetic patients, but could not grade the severity of IC in diabetic patients. Recovery time (RT) of muscle oxygenation differentiated more accurately between severe and moderate claudication than ABPI in diabetics, although RT and ABPI had similar accuracy in non-diabetics. There was a significant correlation between RT and ABPI in non-diabetic patients and patients who had been diabetic for less than 10 years, while there was no correlation in patients who had had diabetes for over 10 years. Conclusion: Measurement of muscle oxygenation during exercise by NIRS graded the severity of IC in diabetic patients more accurately than resting ABPI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Homma, S., Fukunaga, T., & Kagaya, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.252417 · Cited by 123
Cited by
Abnormal Cardiac and Skeletal Muscle Energy Metabolism in Patients With Type 2 Diabetes
Scheuermann-Freestone, M., Madsen, P. L., Manners, D., Blamire, A. M., Buckingham, R. E., Styles, P., Radda, G. K., Neubauer, S., & Clarke, K. (2003) · Circulation · doi:10.1161/01.cir.0000072789.89096.10 · Cited by 525
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
van Hooff, M., Meijer, E. J., Scheltinga, M. R. M., Savelberg, H. H. C. M., & Schep, G. (2022) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12738 · Cited by 20
“Studies using NIRS have shown delayed reoxygenation kinetics and deoxygenation rate in patients with the peripheral arterial disease (PAD) (Cheatle et al., 1991; Kemp et al., 2001; Komiyama et al., 2000).”
BackgroundInfluential
Metadata
- Authors
- Komiyama, T., Shigematsu, H., Yasuhara, H., & Muto, T.
- Venue
- Journal of British Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-04-01
- Volume
- 87
- Issue
- 4
- Pages
- 459-466
- ISSN
- 0007-1323 (ISSN-L)
- 1365-2168
- OpenAlex
- W2024663321
- Cited by
- 79
- References
- 1
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-infrared spectroscopy grades the severity of intermittent claudication in diabetics more accurately than ankle pressure measurement. https://app.cochat.ai/papers/10.1046/j.1365-2168.2000.01381.x
- The paper
- Komiyama, T., Shigematsu, H., Yasuhara, H., & Muto, T. (2000). Near-infrared spectroscopy grades the severity of intermittent claudication in diabetics more accurately than ankle pressure measurement. Journal of British Surgery. https://doi.org/10.1046/j.1365-2168.2000.01381.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.