Acoustic rhinometry, rhinomanometry and the amount of nasal secretion in the clinical monitoring of the nasal provocation test
The DOI matches its Crossref record.
Abstract
Backround: The reliable interpretation of the nasal provocation test in allergy diagnosis requires objective and measurable monitoring parameters for clinical practice. The clinical usefulness of the nasal provocation test has been limited by scanty knowledge of the specificity and sensitivity of the test and a lack of reference values. Objective: To test and compare three objective monitoring parameters of a nasal provocation test in occupational allergic rhinitis. To evaluate the magnitude of the nasonasal effects in a unilateral allergen challenge. Methods: The monitoring parameters of the nasal reaction were derived from the minimum cross‐sectional area on acoustic rhinometry, the nasal resistance on active anterior rhinomanometry and the amount of nasal secretion measured at 15 min intervals for 60 min. Twenty‐three bovine‐allergic dairy and beef cattle farmers and 19 exposed, non‐allergic control subjects were challenged first with a control solution and then with the cow allergen. Results: All the three monitoring parameters showed high specificity and sensitivity in finding allergic and non‐allergic subjects. The secretion parameter was found to be slightly superior to the acoustic rhinometry and rhinomanometry parameters. The side difference in the nasal response between the allergen‐challenged and the contralateral diluent‐challenged cavity was significant for all the parameters among the allergic subjects. The contralateral secretion amount was 1/3 of the ipsilateral secretion, indicating the magnitude of the contralateral nasonasal reflex. A nasonasal reflex was also noted in the nasal patency monitoring. The coefficient of variation was significantly lower for the acoustic rhinometry than for the rhinomanometry (P = 0.0001). The optimal threshold values for a positive test were a secretion amount of 100 mg, a 15% decrease in the minimum cross‐sectional area and a 50% increase in the resistance for the observation period of 30 min and correspondingly 210 mg, 30% and 100% for 60 min. Conclusion: The low‐pressure aspiration of the nasal secretion from the anterior part of the nasal cavity was found to be a reliable and practical monitoring parameter to be used together with acoustic rhinometry or rhinomanometry in the nasal provocation test for clinical purposes. Although significant nasonasal effects took place in the unilateral allergen challenge, the response was more prominent in the allergen‐challenged than in the contralateral diluent‐challenged nasal cavity in most allergic subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diagnostic tools in Rhinology EAACI position paper
Scadding, G., Hellings, P., Alobid, I., Bachert, C., Fokkens, W., van Wijk, R. G., Gevaert, P., Guilemany, J., Kalogjera, L., Lund, V., et al. (2011) · Clinical and Translational Allergy · doi:10.1186/2045-7022-1-2 · Cited by 220
“Measurement of secretion has been introduced as one objective and relevant measurement of nasal provocation test, and that in a unilateral test it has shown to be slightly superior to acoustic rhinometry and rhinomanometry [129].”
EAACI Task Force on Occupational Rhinitis, Moscato, G., Vandenplas, O., Gerth Van Wijk, R., Malo, J. L., Quirce, S., Walusiak, J., Castano, R., De Groot, H., Folletti, I., et al. (2008) · Allergy · doi:10.1111/j.1398-9995.2008.01801.x · Cited by 169
“The major limitation of these tests results from the fact that various criteria have been used for defining a positive response, but there is lack of validated comparison between these criteria (58).”
BackgroundEpidemiology of occupational rhinitis: prevalence, aetiology and determinants: REVIEW
Siracusa, A., Desrosiers, M., & Marabini, A. (2000) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2222.2000.00946.x · Cited by 154
(2011) · PubMed · Cited by 142
S. Carney, A., Powe, D. G., Huskisson, R. S., & Jones, N. S. (2002) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2745.2002.01465.x · Cited by 122
Metadata
- Authors
- PirilÄ, & Nuutinen
- Venue
- Clinical & Experimental Allergy
- Publisher
- Wiley
- Published
- 1998-04
- Volume
- 28
- Issue
- 4
- Pages
- 468-477
- ISSN
- 0954-7894 (ISSN-L)
- 1365-2222
- OpenAlex
- W2160981041
- Cited by
- 60
- References
- 0
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acoustic rhinometry, rhinomanometry and the amount of nasal secretion in the clinical monitoring of the nasal provocation test. https://app.cochat.ai/papers/10.1046/j.1365-2222.1998.00247.x
- The paper
- PirilÄ, & Nuutinen. (1998). Acoustic rhinometry, rhinomanometry and the amount of nasal secretion in the clinical monitoring of the nasal provocation test. Clinical & Experimental Allergy. https://doi.org/10.1046/j.1365-2222.1998.00247.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.