CoChat

Classification of asthma severity: should the international guidelines be changed?

Sawyer, Miles, Lewis, Fitzharris, Pearce, Beasley · 1998 · Clinical & Experimental Allergy
Cited by 47

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: International guidelines recommend that, in addition to symptoms and medication requirements, measurements of forced expiratory volume in one second (FEV 1) and peak expiratory flow (PEF) are necessary for the objective assessment of asthma severity. The guidelines suggest that parity exists between measurements of FEV 1 and PEF when expressed as percentage of predicted normal values, and that asthma severity can be classified as mild, moderate or severe on the basis of FEV 1 and PEF measurements of > 80%, 60–80% and < 60% of predicted values, respectively. Objective: To determine the relationship between measurements of FEV 1 and PEF when expressed as percentage predicted values. Methods: A total of 1198 paired measurements of FEV 1 and PEF were obtained from the medical records of a random sample of 25 adult asthmatic patients attending a hospital‐based chest clinic. Measurements of lung function were expressed as a percentage of predicted normal values, using the European Respiratory Society prediction equations for PEF and FEV 1. For the individual paired measurements, the mean differences between PEF and FEV 1 percentage predicted were calculated. Measurements of lung function were used to determine asthma severity with < 60%, 60–80%, and > 80% predicted FEV 1 and PEF values representing severe, moderate and mild asthma, respectively. The proportion of paired measurements in which differences in classification resulted from the use of FEV 1 or PEF percentage predicted values was then calculated. Results: In asthma of differing severity, there was considerable variability between measurements of FEV 1 and PEF when expressed as percentage predicted values; calculation of the FEV 1% predicted resulted in lower values than those of the PEF percentage predicted, with a mean difference of −17.2% (95% CI −16.3%, −18.1%). There was agreement in classification of asthma severity in only 49.9% (598/1198) of paired measurements. Different prediction equations, while variably altering the degree of misclassification, did not correct the basic differences in the assessment of asthma severity dependent on the use of FEV 1 or PEF. Conclusion: FEV 1 and PEF values, expressed as percentage predicted, are not equivalent. Pending further evaluation, the authors suggest that published asthma guidelines should avoid the assumption of parity between these two measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2222.1998.00451.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Sawyer, Miles, Lewis, Fitzharris, Pearce, & Beasley
Venue
Clinical & Experimental Allergy
Publisher
Wiley
Published
1998-12
Volume
28
Issue
12
Pages
1565-1570
ISSN
  • 0954-7894 (ISSN-L)
  • 1365-2222
OpenAlex
W2121551400
Cited by
47
References
2
FWCI
0.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.