CoChat

Diagnosis of venom allergy by flow cytometry. Correlation with clinical history, skin tests, specific IgE, histamine and leukotriene C4 release

Sainte‐Laudy, Sabbah, Drouet, Lauret, Loiry · 2000 · Clinical & Experimental Allergy
Cited by 133

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Potent allergens such as hymenoptera venoms are capable of inducing severe and life threatening clinical reactions. Percentage of false negative results obtained by the usual diagnostical methods is comprised between 10 and 25% Objective: Evaluation of the sensitivity and the specificity of cellular tests and particularly evaluation of a new flow cytometric method. Methods: Forty‐five allergic patients having experienced a local, a systemic reaction or an anaphylactic shock and 10 controls having undergone hymenoptera stings without clinical reactions were selected on the basis of the clinical history, skin tests and specific IgE. Three cellular tests were performed on the same cell suspensions and in the presence of 2 ng/mL of rIL3: histamine release (RIA), leukotriene C4 release (ELISA) and basophil activation test (flow cytometry after double anti‐IgE FITC, anti‐CD63 PE labelling). Results: As compared to the clinical history, sensitivities of skin tests, specific IgE, flow cytometry, histamine release and leukotriene release were, respectively; 85%, 88%, 100%, 89% and 100%. Flow cytometric analysis of basophil activation showed a significant decrease of the mean fluorescence density and number of IgE positive cells and a significant increase of the number of CD63 positive cells. The 10 controls tested by flow cytometry were negative. Conclusion: As compared to the clinical history and to the other parameters tested here, flow cytometry showed a high sensitivity and a high specificity. The excellent correlation observed between this method and the other cellular tests such as histamine and leukotriene release are in favour of the specificity of flow cytomery and in favour of the use of this method for venom allergy diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2222.2000.00863.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 133

Metadata

Authors
Sainte‐Laudy, Sabbah, Drouet, Lauret, & Loiry
Venue
Clinical & Experimental Allergy
Publisher
Wiley
Published
2000-08
Volume
30
Issue
8
Pages
1166-1171
ISSN
  • 0954-7894 (ISSN-L)
  • 1365-2222
OpenAlex
W2039429964
Cited by
133
References
1
FWCI
2.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.