Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 185

The DOI matches its Crossref record.

Allergen microarray: comparison of microarray using recombinant allergens with conventional diagnostic methods to detect allergen‐specific serum immunoglobulin E

Jahn‐Schmid, B., Harwanegg, C., Hiller, R., Bohle, B., Ebner, C., Scheiner, O., Mueller, M. W.·2003·Clinical & Experimental Allergy

Abstract

Summary: Background The availability of recombinant allergens and recent advances in biochip technology led to the development of a novel test system for the detection of allergen‐specific IgE. Objective To test the performance of this allergen microarray in a serological analytical study. Methods Standard allergens contained in grass pollen (Phl p 1, Phl p 2, Phl p 5 and Phl p 6) and tree pollen (Bet v 1 and Bet v 2) were used as a model system. The detection of allergen‐specific serum IgE using microarrays was compared with standard test systems: CAP/RAST and an in‐house ELISA. In order to test the analytical sensitivity of the assays, geometric dilutions of a serum pool containing high levels of pollen‐specific IgE from allergic individuals were tested in each system. To assess the analytical specificity, the sera of 51 patients with presumptive allergic symptoms were collected before diagnosis. Thereafter, the results for grass/tree‐pollen‐specific IgE were compared. Results The microarray has a good dynamic range similar to the CAP/RAST system. Microarray and ELISA showed comparable analytical sensitivity exceeding the CAP/RAST system. With respect to the analytical specificity, no significant cross‐reactivity of the allergens was observed. For two of the allergens tested, weak positive signals were detected in the microarray test system, whereas they were not detectable by CAP/RAST. Conclusion A good correlation of presently used methods to detect serum IgE and the novel microarray test system was observed. As a next step, a careful validation of this method for a multitude of allergens and a thorough clinical evaluation has to be provided. Microarray testing of allergen‐specific IgE can be presumed to be the method of choice for a prospective component‐resolved diagnosis of Type I allergy, and the basis for the design and monitoring of a patient‐tailored specific immunotherapy in the future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2222.2003.01784.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Jahn‐Schmid, B., Harwanegg, C., Hiller, R., Bohle, B., Ebner, C., Scheiner, O., & Mueller, M. W.
Venue
Clinical & Experimental Allergy
Publisher
Wiley
Published
2003-10
Volume
33
Issue
10
Pages
1443-1449
ISSN
  • 0954-7894 (ISSN-L)
  • 1365-2222
OpenAlex
W2012007700
Cited by
185
References
0
FWCI
5.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Allergen microarray: comparison of microarray using recombinant allergens with conventional diagnostic methods to detect allergen‐specific serum immunoglobulin E. https://app.cochat.ai/papers/10.1046/j.1365-2222.2003.01784.x
The paper
Jahn‐Schmid, B., Harwanegg, C., Hiller, R., Bohle, B., Ebner, C., Scheiner, O., & Mueller, M. W. (2003). Allergen microarray: comparison of microarray using recombinant allergens with conventional diagnostic methods to detect allergen‐specific serum immunoglobulin E. Clinical & Experimental Allergy. https://doi.org/10.1046/j.1365-2222.2003.01784.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.