CoChat

Pulse oximetry in a cohort study of sickle cell disease

HOMI, J., LEVEE, L., HIGGS, D., THOMAS, P., SERJEANT, G. · 1997 · Clinical & Laboratory Haematology
Cited by 65

The DOI matches its Crossref record.

Abstract

Oxygen saturation was determined by pulse oximetry in a representative sample of Jamaican patients with steady-state sickle cell disease in a cohort study from birth. There were 220 with homozygous sickle cell (SS) disease and 142 with sickle cell-haemoglobin C (SC) disease aged 9-18 years, and 122 with a normal haemoglobin (AA) genotype aged 15-18 years. Pulse oximetry (SpO2) values were lower in SS disease (mean [95% confidence interval], 92.5 [92.0-93.0]) than in SC disease (96.7[96.5-96.9]) or AA controls (97.1 [96.8-97.3]). Inhalation of 100% oxygen in SS patients with O2 saturations below 90% consistently increased saturation to 99-100%. In SS disease, SpO2 correlated positively with haemoglobin and fetal haemoglobin and negatively with reticulocyte counts but not with MCHC, MCV or bilirubin level. Mean SpO2 in SS subjects with a normal alpha globin gene complement (mean [SD], 91.7 [3.9]%) was lower than in heterozygotes (93.4 [4.0]%) or homozygotes (96.1 [3.0]%) for alpha+ thalassaemia, the effects of alpha-thalassaemia not being explained by differences in haemoglobin or MCHC. In SS disease, SpO2 levels were not associated with age (within this age range), sex, number of sick clinic visits or number of hospital admissions. Higher SpO2 levels were associated with greater height and weight, more frequent painful crises and less frequent acute chest syndrome, but these associations were not significant after adjustment for haemoglobin level. Desaturation is common in steady-state SS disease and knowledge of the individual's steady-state value may be important in the interpreting low values during acute complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2257.1997.00215.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 65

Metadata

Authors
HOMI, J., LEVEE, L., HIGGS, D., THOMAS, P., & SERJEANT, G.
Venue
Clinical & Laboratory Haematology
Publisher
Wiley
Published
1997-04
Volume
19
Issue
1
Pages
17-22
ISSN
0141-9854 (ISSN-L)
OpenAlex
W2003871198
Cited by
65
References
0
FWCI
1.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulse oximetry in a cohort study of sickle cell disease. https://app.cochat.ai/papers/10.1046/j.1365-2257.1997.00215.x
The paper
HOMI, J., LEVEE, L., HIGGS, D., THOMAS, P., & SERJEANT, G. (1997). Pulse oximetry in a cohort study of sickle cell disease. Clinical & Laboratory Haematology. https://doi.org/10.1046/j.1365-2257.1997.00215.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.