Reproducibility of the low dose dexamethasone suppression test: comparison between direct plasma and salivary cortisol assays
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The low dose dexamethasone suppression test (DST) has been used to detect subtle variations in the feedback suppression of the hypothalamic–pituitary–adrenal axis, which may contribute to the pathogenesis of several diseases including depression, the metabolic syndrome and coronary artery disease. Little is known about the reproducibility of this test, or whether the test can be combined with analysis of salivary cortisol which would offer a significant advantage over plasma in population studies. SUBJECTS AND DESIGN: A low dose DST was carried out in 29 healthy subjects (14 men, 15 women), aged 24–54 (mean 35.1) years, on two separate occasions 1–10 weeks apart. Following the administration of 0.25 mg dexamethasone (DXM) at 2200 h, plasma and saliva were sampled at 0830 h the next day. Cortisol was measured by radioimmunoassay in plasma and time‐resolved immunofluorescent assay (‘DELFIA’) in saliva. Bland–Altman plots were produced for post‐DXM plasma and salivary cortisol measures and used to derive a coefficient of repeatability for each measure, which describes the range of cortisol measurements within which 95% of repeated measurements will fall. RESULTS: The baseline, pre‐DXM cortisol concentrations were far more variable for saliva (mean 16.5, range 4.4–34 nmol/l) than for plasma (mean 407.5; range 232–958 nmol/l). Following DXM both measurements showed an approximately 30% suppression from baseline but the variability of salivary cortisol was much greater. From the Bland–Altman plots the 95% range for the differences about their mean was calculated and used as an indication of repeatability. For plasma 95% of differences were within 0.78 log units, indicating that a repeated measurement was approximately half as small or twice as large as the first. For saliva 95% of differences were within 1.64, indicating that a repeated measurement was approximately five times as small or five times as large as the first. CONCLUSIONS: Assessment of dexamethasone suppression by salivary cortisol measurement is far less repeatable than the use of plasma cortisol. In the context of field studies of dexamethasone suppression, salivary cortisol measurements may only be appropriate for large numbers of subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Carroll, B. J. (1981) · Archives of General Psychiatry · doi:10.1001/archpsyc.1981.01780260017001 · Cited by 2,243
Cited by
Measuring cortisol in human psychobiological studies
Levine, A., Zagoory-Sharon, O., Feldman, R., Lewis, J. G., & Weller, A. (2007) · Physiology & Behavior · doi:10.1016/j.physbeh.2006.08.025 · Cited by 472
Early-life stress and HPA axis trigger recurrent adulthood depression
Juruena, M. F. (2014) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2013.10.020 · Cited by 253
McBeth, J., Silman, A. J., Gupta, A., Chiu, Y. H., Ray, D., Morriss, R., Dickens, C., King, Y., & Macfarlane, G. J. (2007) · Arthritis & Rheumatism · doi:10.1002/art.22336 · Cited by 233
PTSD and stress sensitisation: A tale of brain and body
Stam, R. (2007) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.11.010 · Cited by 211
Different responses to dexamethasone and prednisolone in the same depressed patients
Juruena, M. F., Cleare, A. J., Papadopoulos, A. S., Poon, L., Lightman, S., & Pariante, C. M. (2006) · Psychopharmacology · doi:10.1007/s00213-006-0555-4 · Cited by 147
“In contrast, salivary cortisol responses to dexamethasone show a large variability (Reynolds et al. 1998).”
Metadata
- Authors
- Reynolds, Bendall, Whorwood, Wood, Walker, & Phillips
- Venue
- Clinical Endocrinology
- Publisher
- Wiley
- Published
- 1998-09
- Volume
- 49
- Issue
- 3
- Pages
- 307-310
- ISSN
- 0300-0664 (ISSN-L)
- 1365-2265
- OpenAlex
- W2123346492
- Cited by
- 43
- References
- 2
- FWCI
- 0.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of the low dose dexamethasone suppression test: comparison between direct plasma and salivary cortisol assays. https://app.cochat.ai/papers/10.1046/j.1365-2265.1998.00549.x
- The paper
- Reynolds, Bendall, Whorwood, Wood, Walker, & Phillips. (1998). Reproducibility of the low dose dexamethasone suppression test: comparison between direct plasma and salivary cortisol assays. Clinical Endocrinology. https://doi.org/10.1046/j.1365-2265.1998.00549.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.