CoChat

Establishment of reference values for standard dose short synacthen test (250 μg), low dose short synacthen test (1 μg) and insulin tolerance test for assessment of the hypothalamo–pituitary–adrenal axis in normal subjects

Gonzálbez, Villabona, Ramón, Navarro, Giménez, Ricart, Soler · 2000 · Clinical Endocrinology
Cited by 72

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess the integrity of the hypothalamo–pituitary–adrenal(HPA) axis, many authors have proposed the short synacthen test (ACTH 1–24, Tetracosactrin) as a replacement for the insulin tolerance test (ITT). The aim of this study was to compare the plasma cortisol response obtained with both short synacthen tests (high dose (HDT, 250 μg) and low dose (LDT, 1 μg)) with the peak reached during the ITT in healthy volunteers, and to establish the plasma cortisol cut‐off level in each test. SUBJECTS AND METHODS: Thirty healthy subjects (16 F, 14 M), mean age 34 years, underwent both short synacthen tests. Twenty healthy subjects, 15 of whom (11 F, nine M) belonged to the above group, mean age 30 years, underwent an ITT. Plasma cortisol was measured using a chemiluminiscence immunoassay. RESULTS: There were no differences between plasma cortisol 30 minutes after both short synacthen tests (HDT: 684 ± 123, LDT: 669 ± 119 nmol/l) and the peaks reached with the LDT (691 ± 123 nmol/l) and the ITT (673 ± 99 nmol/l).The only difference (P < 0.001) was found in the comparison of plasma cortisol peak reached with the HDT (802 ± 142 nmol/l) with the other tests. Plasma cortisol levels obtained in the 5th percentile in each test were: at + 30 minutes: (HDT: 537, LDT: 489 nmol/l), peak: (HDT 649, LDT 498, ITT: 539 nmol/l). CONCLUSIONS: Comparison of the plasma cortisol response at + 30 minutes with both short ACTH tests and the peak in the insulin tolerance test did not reveal differences. Each test, for each time point and for each biochemical method, requires its own minimum threshold of normality to assess the hypothalamo–pituitary–adrenal axis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2265.2000.01028.x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 72

Metadata

Authors
Gonzálbez, Villabona, Ramón, Navarro, Giménez, Ricart, & Soler
Venue
Clinical Endocrinology
Publisher
Wiley
Published
2000-08
Volume
53
Issue
2
Pages
199-204
ISSN
  • 0300-0664 (ISSN-L)
  • 1365-2265
OpenAlex
W2115568720
Cited by
72
References
13
FWCI
2.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Establishment of reference values for standard dose short synacthen test (250 μg), low dose short synacthen test (1 μg) and insulin tolerance test for assessment of the hypothalamo–pituitary–adrenal axis in normal subjects. https://app.cochat.ai/papers/10.1046/j.1365-2265.2000.01028.x
The paper
Gonzálbez, Villabona, Ramón, Navarro, Giménez, Ricart, & Soler. (2000). Establishment of reference values for standard dose short synacthen test (250 μg), low dose short synacthen test (1 μg) and insulin tolerance test for assessment of the hypothalamo–pituitary–adrenal axis in normal subjects. Clinical Endocrinology. https://doi.org/10.1046/j.1365-2265.2000.01028.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.