Cited by 12Thyroid Disorders and TreatmentsCardiac electrophysiology and arrhythmiasPharmacogenetics and Drug Metabolism

Normalization of peripheral thyroid hormone metabolism induced by successful chronic amiodarone treatment in patients with ventricular arrhythmias

Iervasi, G., Clerico, A., Berti, S., Pilo, A., Biagini, A., Bianchi, R., Donato, L.·1996·European Journal of Clinical Investigation

Abstract

Amiodarone, an antiarrhythmic agent, is also known to have important effects on the peripheral metabolism of thyroid hormones; the relationship between these two effects of the drug, however, is not well established. We tested the hypothesis that the antiarrhythmic effect of amiodarone might be mediated by its effect on the metabolism of thyroid hormones. Peripheral thyroid hormone metabolism was investigated using a double-tracer ([125I]-T4 and [131I]-T3) procedure in 10 normal volunteers and 10 euthyroid patients with complex ventricular arrhythmias before and during 6 months' amiodarone treatment. The underlying cardiac disease was coronary artery disease in four cases, dilated cardiomyopathy in three and idiopathic arrhythmias in three. In all but one patient with complex ventricular arrhythmias amiodarone treatment resulted in a reduction of > or = 80% of premature ventricular contractions and complete suppression of episodes of ventricular pairs or ventricular tachycardia. In all cases successful treatment with amiodarone was accompanied by normalization of all kinetic parameters: T4 to T3 conversion ratio and T3/T4 molar ratio of production decreased to mean values of 24.7 +/- 17.5% and 0.35 +/- 0.22% respectively, whereas T4 production rate increased (mean value 75.9 +/- 30.0 nmol day-1 m-2). Our kinetic data indicate that long-term therapy with amiodarone, when effective in suppressing cardiac arrhythmias, also reduces peripheral T4 to T3 conversion, hence restoring…

Integrity signals

Registry

Crossref · 10.1046/j.1365-2362.1996.127300.x

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • To improve reliability and reduce interassay variability, each serum sample was assayed on several occasions in the same experiment and in different sessions (at least three times).

    “To improve the reliability of measurements and to reduce the effects of interassay variability, we assayed each serum sample on several occasions in the same experiment and in different sessions (at least three times) (24).”

Cited by

Sorted by citations

Authors
Iervasi, G., Clerico, A., Berti, S., Pilo, A., Biagini, A., Bianchi, R., & Donato, L.
Affiliations
  • Istituto di Fisiologia Clinica (IT)
  • University of Pisa (IT)
Corresponding author
Iervasi, G.
Venue
European Journal of Clinical Investigation
Publisher
Wiley
Published
1996-05
Volume
26
Issue
5
Pages
382-390
ISSN
  • 0014-2972 (ISSN-L)
  • 1365-2362
OpenAlex
W2095393755
Cited by
12
References
0
Citations by year
2021: 1 · 2017: 1 · 2016: 1 · 2014: 1
FWCI
0.27
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Clinical Investigation (publishedVersion)
  • PubMed (publishedVersion)
  • CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Pharmacogenetics and Drug Metabolism
Keywords
amiodarone, T4 to T3 conversion, ventricular arrhythmias, antiarrhythmic mechanism, thyroid hormone kinetics, coronary artery disease, dilated cardiomyopathy, idiopathic ventricular arrhythmia, ventricular tachycardia
MeSH terms
Aged, Aged, 80 and over, Amiodarone, Analysis of Variance, Anti-Arrhythmia Agents, Cardiac Complexes, Premature, Female, Humans, Kinetics, Male, Middle Aged, Thyroxine, Triiodothyronine, Tachycardia, Ventricular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review